Assembly and connection
20
05.00 | KSF3, KSF3-LH, KSF3-F | TANDEM Clamping Force Block | en | 1467140
5.1 Assembly of the Clamping Block on the machine table
34
Cylindrical pins Ø m6
82
Fitting screw Ø f7
84
Screw DIN EN ISO 4762
85
Clamping sleeve DIN EN ISO 13337
NOTE
• For vertical installation, the openings of the coolant drain (V)
must always face downwards
• Surface
"X"
is parallel to the guideway of the base jaws (item 2)
in order to be able to align the clamping force block on the
machine table or check the positioning.
Assembly with clamping sleeves:
Mount the clamping force block
on the machine table together with clamping sleeves (item 85) and
screws (item 84).
Assembly with fitting screws:
There are two fittings in the housing (item 1) that, along with the
fitting screws (item 82), are used to center the clamping force
block on the machine table with repeat accuracy. Do not realign
the clamping force block after removing it from the machine table
(e.g. after replacing the seals). When using fitting screws (item 82),
these are used instead of the clamping sleeves (item 85) and two
of the four screws (item 84).
Mounting with cylindrical pins (Z variant):
The clamping force block is fastened to the machine table with 4
screws (item 84). The two cylindrical pins (item 34) are used for
alignment with repeat accuracy. Do not realign the clamping force
block after removing it from the machine table (e.g. after replacing
the seals).