![SCHUNK STM 560V Series Assembly And Operating Manual Download Page 33](http://html1.mh-extra.com/html/schunk/stm-560v-series/stm-560v-series_assembly-and-operating-manual_1215781033.webp)
Start-up
04/STM-560V/en/2010-12-10/SW
33
2. Select the communication interface, establish communication
with the module and configure the converter.
3. Check the encoder signal and the signal of the temperature
sensor.
4. Control the STM and optimize the parameters.
5. Check the bearing noise at regular intervals.
Note
If the unit is referenced via the encoder's zero pulse, free motion
must be ensured within the range of ± 360°.
If the STM is used in a multiple axis system, it is recommended to
put the axes into operation individually.
To avoid collisions, prior to the first movement, check the
alignment of the STM, the set direction of counting of the
measuring system and the motor's direction of rotation.
Note
This brief instruction is solely relevant for the simple start-up of
the STM with either the Bosch IndraDrive C or Siemens
Sinamics. Please read the manuals for both converters
thoroughly before putting the motor into operation.
8.1
Start-up of the Bosch IndraDrive C
This description is valid for the firmware version MPH-05V12-D5
and the IndraWorks Version 8.6.172.0:
1. Connect the converter to the three-phrase power network via
terminal X1.
2. Connect the red power cable and the white sensor cable to
the STM.
3. Connect the 15-pin D-Sub plug of the sensor cable to terminal
X4.
4. Connect the free ends of the power cable to terminal X3.
Connection of the
converter
to the STM