Handling and operation
22
02.01|RST-P 060 / 087|en
NOTICE
It must be possible to completely air-bleed the drive!
For operation, full air-bleeding of the drive is provided for steps
(3)
→(4).
•
Use (1x 5/3 directional control valve or 2x 3/2 control valves)
for connections A and B.
RST-P in home position for operation of clockwise pulsing
•
Cycle ring in operating position and locked
•
Pressurized connection: D
•
Drive piston in end position ACW
•
Pressurized connection: B
•
Sensor assignment: End position ACW
1 RST-P in home position:
Actuation of connection D → C
(lo
cked → unlocked) lock bolts release cycle ring. Up to step 2:
Waiting time at least 0.1 s
2 Locking mechanism fully released: Actuation of connection B
→ A (turning ACW → turning CW). Cycle ring is turned by pr
e-
defined pitch.
3 Sensor reaches end position CW:
Actuation of connection C →
D (locked → unlocked). Simultaneous air
-bleeding of connec-
tions A, B. Lock bolts lock the cycle ring. Up to step 4: Waiting
time at least 0.1 s
4 New position of the cycle ring is locked: Pressurize connec-
tion A.
5 Cycle ring is locked, connection A is pressurized: Actuation of
connection A → B (turning CW → turning ACW). Drive piston
is
decoupled and is moved back. As of sensor leaving end posi-
tion CW (falling edge), operations can be performed on the ro-
tary table before new pulsing starts.
6 Sensor reaches end position ACW: Drive piston is in end posi-
tion ACW, home position is reached.
7 Introduction of new pulsing
Description of clock-
wise pulsing
Summary of Contents for RST-P 060
Page 38: ...Notes 38 02 01 RST P 060 087 en Notes ...
Page 40: ...40 02 01 RST P 060 087 en ...