38
03.00 | RP / RW / RC | Assembly and Operating Manual | en | 389392
8.2.2 Maintenance and lubrication intervals
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Interval (million cycles)
Maintenance work
2
Check for leaks
4
(recommendation)
Re-lubricate the gear rack
and pinion unit (RM-F 15,
RM-F 21)
2
Variant for
sizes 12 and 15:
6
Replace shock absorber
Recommendation for safe operation
8.2.3 Lubricants/Lubrication points
• All product bearings are life-time lubricated and do not need to
be re-lubricated.
• When disassembling the product for repairs, all bearings have
to be cleaned and re-lubricated.
Lubrication point, Lubricant
Lubricant point
Lubricant
Gear rack and pinion unit *
Isoflex-Topas NCA 52
(from Klüber)
All seals **
Rolling element and sliding sur-
faces of the bearings **
* For RM06/08/10/12, only after disassembly of the prodct for repairs
** All products, only after disassembly of the product for repairs
Gear rack and pinion
unit greasing area
(RM15, RM21 only)
Ø
Lubricate the product at the designated areas.