Assembly and settings
03.00 | RP / RW / RC | Assembly and Operating Manual | en | 389392
19
NOTICE
Pressure medium:
The unit must not under any circumstances be operated with
oiled air before operation with unoiled air (washing out of factory
lubrication).
NOTICE
One-way flow control valves must be installed at the air connec-
tions for operation.
Alternatively, hose throttles can also be used.
NOTE
• Observe the requirements for the compressed air supply,
Technical data
[
}
16].
• In case of compressed air loss (cutting off the energy line), the
components lose their dynamic effects and do not remain in a
secure position. However, the use of a SDV-P pressure mainten-
ance valve is recommended in this case in order to maintain the
dynamic effect for some time. Product variants are also offered
with mechanical gripping force via springs, which also ensure a
minimum clamping force in the event of a pressure drop.
Use connecting wires with the same or a larger cross-section as
the connection thread.
See the catalog for precise information about the position and size
of the connection geometries.
Air connections
Connection
Function
A
Clockwise rotation (direction of arrow)
B
Counterclockwise rotation
C
Open gripper
D
Close gripper