Assembly
30
13.00 | MPG-plus | Assembly and operating manual | en | 389216
5.3.5.2 Size MPG-plus 64
For these sizes no holder is necessary, but the sensor is secured in
the vertical groove of the gripper. Mounting the sensor in the
horizontal groove is not possible.
Ø
If a T-nut (1) is available, set the T-nut to dimension L3, see
table "Setting dimensions". Slide sensor (2) to the stop in the
groove.
OR: If no T-nut (1) is available, slide the sensor (2) into the
groove and adjust distance L3, see table "Setting dimensions".
Ø
Secure the sensor using the set-screw.
Tightening torque: 10 Ncm
Ø
Adjust sensor, see Assembly and Operating Manual for the
sensor.
Setting dimensions for the T-nuts and sensors for MPG-plus 64
L1
Projection of the sensor
L3
Distance of the housing to the front of the sensor
Setting dimensions
Size
L1 [mm]
L3 [mm]
MPG-plus 64
-3.1
-25.1
MPG-plus 64 IS
1.2
-20.8
MPG-plus 64 AS
-18.0
-40