_________________________________________________________________________________________
schunk.com
XND.00015.012_A – 10/2018
27
When installing the mechanical force cassette into the fixed jaw it is necessary to refill it with
low-viscosity gear grease,
preferably with a large syringe,
to ensure
sufficient lubrication
!
Low-viscosity gear
grease type: for example, Valvoline Semi Fluid Grease 00
Filling through the hole in the
mechanical force cassette.
Filling amount in already used mechanical force
cassette:
10 - 15 ml. (for example, after cleaning
)
Filling amount in a new mechanical force cassette:
50 - 55 ml. (for example, by replacement)
Removing the fixed jaw
1. Slightly loosen the cylinder screw M12x120.
2. Mobile fixed jaw can now be moved and re-
moved.
Replacing the fixed jaw
1. Align the mobile fixed jaw with the outside of the
base plate and slide it in.
2. cylinder screws M12x120 tighten with 90 Nm.
7.5
Assembly, general
Carry out assembly in the reverse order.
For the assembly it is important to ensure that the sealing rings are correctly inserted into the
fixed jaw and the spindle. Apply adequate lubrication to all components during assembly.
Important:
The threaded parts of the telescope tubes may only be oiled, for example with MOTOREX
Supergliss 68 K to ISO VG 68, not lubricated with grease.
Torque:
Cover: cylinder screws NK M6 x 10 (8.8): 10 Nm