![SCHUNK KSP plus-BWM Series Assembly And Operating Manual Download Page 35](http://html1.mh-extra.com/html/schunk/ksp-plus-bwm-series/ksp-plus-bwm-series_assembly-and-operating-manual_1215939035.webp)
Trouble shooting
04.00|1151449 KSPplus-BWM, KSP-LHplus-BWM |en
35
Possible cause
Solution(s)
The changing jaws have been switched.
Changing and base jaw numbers must match.
Increased changing jaw "rear-up"
Clean interfaces between base and changing
jaws.
Set changing jaw firmly into change interface by
pulling backward.
Clamping block does not complete stroke
Possible cause
Solution(s)
Chips or dirt between covering strip
and base jaws
Unscrew the covering strip (item 7) and remove
chips and dirt
Clamping force getting weaker
Possible cause
Solution(s)
Clamping block not sealed tightly
Check connection and seal screws; reseal or
replace
Seals damaged
replace all the seals (see sealing kit lists
Inadequate lubrication
Lubricate the lubrication nipples with LINO MAX
Clamping block movement jerky
Possible cause
Solution(s)
Steel guide rollers on sliding surfaces
not greased