Assembly and installation
05.01|EVG 55|en
47
Connecting ground cable
Ground connection
1
Screw
4
Toothed lock washer
2
Plain washer
5
Product
3
Cable lug
6
Ground marking
A ground connection must be established between the product and
the machine on the customer's premises.
The ground cable must be mounted to the threaded hole marked by
the ground marking. If there is no such threaded hole, mount the
ground cable to another free threaded hole of the product.
NOTE
Do not mount the ground cable to a threaded hole that is already
mechanically used for something else, e.g. for screwing on accessory.
Always mount the ground cable individually.
Always use all components of the screw connection and install them
in this order: plain washer, cable lug, and toothed lock washer. See
"Ground connection" diagram.
5.5