![SCHUNK ERT 12 Translation Of Original Operating Manual Download Page 85](http://html1.mh-extra.com/html/schunk/ert-12/ert-12_translation-of-original-operating-manual_1215907085.webp)
Assembly
Sensor plug
connection
assignment, DRIVE-
CLiQ
Pin
Pin allocation
Note
1
+ Us
Motor encoder supply voltage
2
n.c.
-
3
RXP
Process data channel
4
RXN
Process data channel
5
GND
Ground connection
6
TXN
Process data channel
7
TXP
Process data channel
8
N.C.
-
Shield
Housing potential
Power cable
connection
assignment
The cable colors and designations in the following tables apply to
the SCHUNK connection cable.
Connection assignment of the blue power cable for Bosch Rexroth
IndraDrive / IndraDrive CS and Siemens S120 Sinmics
Function
Signal
Cable designation
Power
U
Black (a)
V
Black (b)
W
Black (c)
PE
Green/Yellow
Brake
B-
Black (4)
B+
Black (5)
Temperature sensor T-
Black (6) [not with S120
Sinamics]
T+
Black (7) [not with S120
Sinamics]
85