Maintenance
7 Maintenance
7.1 Cleaning
Remove contamination from ERD at regular intervals (e.g. with
lint-free cloth).
7.2 Inspections
• At regular intervals, check that all the electrical connections are
connected firmly.
• Check cables for damage at regular intervals. In the event of
defects, turn off the system and replace cables.
7.3 Notes on the electrical and pneumatic rotary feed-through
The pneumatic seal kit and electric grinding unit are a wearing
part. Depending on the operating conditions, these have to be
replaced in the production facility. Their expected life span is 5
million revolutions or cycles.
7.4 IP 54 version
Note that attaching the IP54 seal kit alters the ERD's interfering
contour.
7.4.1 Maintenance interval
The IP 54 version seal kit is a wearing part. Depending on the
ambient and operating conditions, it has to be replaced if any leaks
occur.
To ensure tightness, observe the following maintenance schedule
Seal replacement
interval [million revolutions or cycles]
5
Operation under extreme ambient conditions (e.g. casting dust or
abrasive dust) can significantly shorten the life span of the seals
(thereby reducing the maintenance interval).