4.5 Adjusting, removing and replacing the return spring for units
built in or after June 2016
The unit contains 4 compression springs for the return position
function.
The force values on the unit can not be changed anymore (applies
to units delivered since June 2016).
Replacing springs
Removing / Replacing
Position of the item numbers
Ø
Remove the set-screws (50).
Ø
Remove the spring sleeve (4) and take out the springs (15).
As standard, three springs are available for each size. Special
springs on request.
The new springs are assembled in the reverse order.