Schumacher SpeedCharge 10000A Owner'S Manual Download Page 3

3

IMPORTANT SAFETY INSTRUCTIONS

WARNING: 

Handling the cord on this

product or cords associated with
accessories sold with this product, will
expose you to lead, a chemical known
to the State of California to cause
cancer and birth defects or other
reproductive harm. 

Wash hands after

handling.

• Read all instructions and cautions

printed on the battery charger,
battery, and vehicle or equipment
using battery.

• Use charger only on lead-acid type

rechargeable batteries, such as those
used in cars, trucks, tractors, air-
planes, vans, RV’s, trolling motors,
etc. This charger is not intended to
supply power to a low voltage
electrical system other than in a
starter-motor application.

Never 

use charger for charging dry

cell batteries that are commonly used
with home appliances like radios,
stereos, remote controls, etc. These
batteries may burst and cause
personal injury.

• Do not disassemble charger. Take it

to a qualified service professional if
service or repair is required. Incorrect
assembly may result in fire or
electrical shock.

WARNING – RISK OF EXPLOSIVE GASES

WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BAT-
TERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY
OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT
EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL
AND FOLLOW THE INSTRUCTIONS EXACTLY.

SAVE THESE INSTRUCTIONS

• To reduce risk of electrical shock,

unplug the charger from the outlet
before attempting any maintenance
or cleaning.

• Always charge battery in a well-

ventilated area.

WARNING: 

Battery chargers get hot

during operation and must have
proper ventilation. Air needs to flow
around entire charger. Do not set
charger on flammable materials like
carpeting, upholstery, paper, card-
board, etc. Charger may damage
leather and melt plastic and rubber.

HELP US HELP YOU ——
Remember:

Place

 charger as far away from the

battery being charged as the charger
cables will permit.

Do not

 expose charger to rain or snow.

Never

 charge a frozen battery. If battery

fluid (electrolyte) becomes frozen, bring
battery into a warm area to thaw before
you begin charging.

Never

 allow battery acid to drip on

charger when reading specific gravity or
filling battery.

Never

 set a battery on top of the

charger.

To reduce risk of battery explosion, follow these instructions and those published by
battery manufacturer and manufacturer of any equipment you intend to use in vicinity
of battery. Review cautionary marking on these products and on engine.

Summary of Contents for SpeedCharge 10000A

Page 1: ...WNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 10000A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Returns P O Box 280 1025 E Thomps...

Page 2: ...cur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged t...

Page 3: ...RATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY SAVE T...

Page 4: ...plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching yo...

Page 5: ...e voltage of battery by referring to vehicle owner s manual or the battery markings Be sure to set the charger to the 6V or 12V mode accordingly Charge battery initially at charger s lowest rate Clean...

Page 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Page 7: ...er cord before attempting to disconnect the charger clamps Then standing away from the battery remove the output clamp from the CHARGINGBATTERYREMOVEDFROMTHEVEHICLE NEGATIVE battery post Finally remov...

Page 8: ...the type of battery to be charged to one of the following 10000A CONTROL PANEL 12V REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent caps and ar...

Page 9: ...0V 2 Amp charge with battery detected O O xx or xx xV 15 Amp charge activated O O xx or xx xV 40 Amp charge activated O O xx or xx xV Charge complete Maintain Mode started O 100 or xx xV 100A Engine...

Page 10: ...sed within the first ten minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been cha...

Page 11: ...minutes If the charger resets it sets itself for a 2A charge and 12V REGULAR battery While waiting for cranking the digital display shows the battery voltage it can t be set to percent USING YOUR ENG...

Page 12: ...signed for such batteries Activation of the spe cial desulfation mode is indicated by blinking the CHARGING LED If suc cessful normal charging will resume after the battery is desulfated The CHARGING...

Page 13: ...at period If the vehicle will only be operated for a short period short drive the battery might need to be charged again before it could start the vehicle again Reviving your battery If you only wish...

Page 14: ...if it is determined that the battery can accept the higher rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started the di...

Page 15: ...nnecting the negative large battery or a bank of battery clip Select the batteries requiring more desired charge rate and power than a 40 15 Amp battery type again if charger can deliver within necess...

Page 16: ...ANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WARRANTY THE MANUFACTURER MAKES NO WARRANTY OF MERCHANTABIL...

Reviews: