Schumacher SpeedCharge 10000A Owner'S Manual Download Page 10

10

USING THE BUILT-IN BATTERY TESTER

OVERVIEW

This battery charger has a built-in
battery tester that displays either an
accurate battery voltage or an estimate
of the battery’s relative charge based on
the battery voltage and the Battery
Council International scale.

TESTING SEQUENCE

There are four basic steps required to
use the 10000A as a battery tester.
1. Connect the charger battery clamps to

the battery. Be sure to follow all of the
precautions listed under “OPERATING
INSTRUCTIONS”.

2. Connect the charger power cord to a

120 VAC outlet. Again, be sure to follow
all of the precautions listed under “OP-
ERATING INSTRUCTIONS”.

3. If necessary, press the Battery Type

button until the correct type is indi-
cated.

4. Read the voltage on the digital LED or

press the display mode button to set
the tester to “Battery %” and read the
battery percent.

TESTER AND CHARGER

When first turned on, the 10000A
operates only as a tester, not as a
charger. To continue to use it as only a
tester, avoid pressing the CHARGE
RATE switch button. Selecting a charge
rate activates the battery charger and
deactivates the tester.

POWER-UP IDLE TIME LIMIT

If no switch button is pressed within ten
minutes after the unit is first powered
up, the unit will automatically switch
from tester to charger, if a battery is
connected. In that case, the unit will be
set for the 2A charge rate and 12V
REGULAR battery type.

TESTER WITHOUT TIME LIMIT

If either the DISPLAY MODE or BAT-
TERY TYPE button is pressed within the
first ten minutes after the unit is
powered up, the unit will remain a tester
(not a charger) indefinitely, unless a
charge rate is selected.

TESTING AFTER CHARGING

After the unit has been changed from
tester to charger (by selecting a charge
rate), it remains a charger as long as it
has power. Disconnect and reconnect
the power to change the unit back to a
tester.

TESTER STATUS LEDs

When the 10000A is operating as a
battery tester, the status LEDs light
under the following conditions.
• The CHARGED (green) LED will light

if a charged battery is tested.

• The CHARGING (yellow) LED does

not light in the battery test mode.

• The CHECK (red) LED lights unless a

properly connected battery is de-
tected.

• When the tester display mode is set

to voltage, none of the Status LEDs
light.

INITIAL PERCENT CALCULATION

When a battery % is calculated for the
first time after connecting a battery, the
digital LED will show two dashes (“--”)
for a period as long as several seconds
while the tester analyzes the battery.

NOTES FOR TESTING BATTERY %

A recently charged battery could have a
temporarily high voltage due to what is
known as “surface charge”. The voltage
of such a battery will gradually drop
during the period immediately after the
charging system is disengaged.
Consequently, the tester could display
inconsistent values for such a battery.
For a more accurate reading, the
surface charge should be removed by
temporarily creating a load on the
battery, such as by turning on lights or
other accessories.

The battery % ranges from 0 to 100.

The battery tester is only designed to
test batteries. Testing a device with a
rapidly changing voltage could yield
unexpected or inaccurate results.

Summary of Contents for SpeedCharge 10000A

Page 1: ...WNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 10000A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Returns P O Box 280 1025 E Thomps...

Page 2: ...cur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged t...

Page 3: ...RATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY SAVE T...

Page 4: ...plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching yo...

Page 5: ...e voltage of battery by referring to vehicle owner s manual or the battery markings Be sure to set the charger to the 6V or 12V mode accordingly Charge battery initially at charger s lowest rate Clean...

Page 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Page 7: ...er cord before attempting to disconnect the charger clamps Then standing away from the battery remove the output clamp from the CHARGINGBATTERYREMOVEDFROMTHEVEHICLE NEGATIVE battery post Finally remov...

Page 8: ...the type of battery to be charged to one of the following 10000A CONTROL PANEL 12V REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent caps and ar...

Page 9: ...0V 2 Amp charge with battery detected O O xx or xx xV 15 Amp charge activated O O xx or xx xV 40 Amp charge activated O O xx or xx xV Charge complete Maintain Mode started O 100 or xx xV 100A Engine...

Page 10: ...sed within the first ten minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been cha...

Page 11: ...minutes If the charger resets it sets itself for a 2A charge and 12V REGULAR battery While waiting for cranking the digital display shows the battery voltage it can t be set to percent USING YOUR ENG...

Page 12: ...signed for such batteries Activation of the spe cial desulfation mode is indicated by blinking the CHARGING LED If suc cessful normal charging will resume after the battery is desulfated The CHARGING...

Page 13: ...at period If the vehicle will only be operated for a short period short drive the battery might need to be charged again before it could start the vehicle again Reviving your battery If you only wish...

Page 14: ...if it is determined that the battery can accept the higher rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started the di...

Page 15: ...nnecting the negative large battery or a bank of battery clip Select the batteries requiring more desired charge rate and power than a 40 15 Amp battery type again if charger can deliver within necess...

Page 16: ...ANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WARRANTY THE MANUFACTURER MAKES NO WARRANTY OF MERCHANTABIL...

Reviews: