Schumacher SpeedCharge 10000A Owner'S Manual Download Page 12

12

USING YOUR BATTERY CHARGER

OVERVIEW

Using this battery charger is very
simple. First, connect the battery and AC
power following the precautions listed
under “OPERATING INSTRUCTIONS”.
Then select the appropriate BATTERY
TYPE and CHARGE RATE for your
battery. The charger will then do
everything automatically. This section
explains a few details.

CHARGING: 

If the charger does not

detect a properly connected battery, the
CHECK (red) LED will light continuously
until such a battery is detected. Charg-
ing will not begin while the CHECK light
is on. When charging begins, the
CHARGING LED will be lit.

AUTOMATIC SHUT OFF:

 When the 2A,

15A or 40A charge rate is selected, the
charger is set to perform an automatic
charge. When an automatic charge is
performed, the charger stops charging
automatically after the battery is
charged.

ABORTED CHARGE: 

If charging can’t

be completed normally, charging will be
aborted. When charging is aborted, the
charger’s output is shut off and the red
CHECK LED and digital LED blink on
and off (at opposite times). In that state,
the charger ignores all buttons. To reset
from after an aborted charge, either
disconnect the battery or unplug the
charger.

DESULFATION MODE:

 If a battery is left

discharged for an extended period, it
could become sulfated and not accept a
normal charge. If the charger detects a
sulfated battery, the charger will switch
to a special mode of operation designed
for such batteries. Activation of the spe-
cial desulfation mode is indicated by
blinking the CHARGING LED. If suc-
cessful, normal charging will resume
after the battery is desulfated. The
CHARGING LED will then stop blinking

and light continuously. Desulfation
could take up to 10 hours. If desulfation
fails, charging will be aborted and the
CHECK (red) LED will blink.

COMPLETION OF CHARGING:

 Charge

completion is indicated by the
CHARGED (green) LED; when lit, the
charger has stopped charging and
switched to the Maintain Mode of
operation.

MAINTAIN MODE

: When the

CHARGED (green) LED is lit, the
charger has started Maintain Mode. This
mode of operation is also known as
Float-Mode Monitoring. In this mode,
the charger keeps the battery fully
charged by delivering a small current,
when necessary. The voltage is main-
tained at a level determined by the
BATTERY TYPE selected.

GENERAL CHARGING NOTES:

The unit is designed to control its
cooling fan for efficient operation.
Consequently, it is normal for the fan to
start and stop when maintaining a fully
charged battery. The fan does not run in
Tester Mode.

If the charge mode is changed after
charging has started (by pressing the
CHARGE RATE or BATTERY TYPE
button), the charging process will be
restarted.

The voltage displayed during charging is
the charging voltage and usually will be
higher than the battery’s resting voltage.

If the 6V REGULAR battery type has
been selected, and the battery voltage
exceeds 8.5 VDC, the charging process
will be aborted (see ABORTED
CHARGE above). The charger will not
charge a 12V battery if “6V REGULAR
has been selected.

Summary of Contents for SpeedCharge 10000A

Page 1: ...WNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 10000A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Returns P O Box 280 1025 E Thomps...

Page 2: ...cur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged t...

Page 3: ...RATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY SAVE T...

Page 4: ...plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching yo...

Page 5: ...e voltage of battery by referring to vehicle owner s manual or the battery markings Be sure to set the charger to the 6V or 12V mode accordingly Charge battery initially at charger s lowest rate Clean...

Page 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Page 7: ...er cord before attempting to disconnect the charger clamps Then standing away from the battery remove the output clamp from the CHARGINGBATTERYREMOVEDFROMTHEVEHICLE NEGATIVE battery post Finally remov...

Page 8: ...the type of battery to be charged to one of the following 10000A CONTROL PANEL 12V REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent caps and ar...

Page 9: ...0V 2 Amp charge with battery detected O O xx or xx xV 15 Amp charge activated O O xx or xx xV 40 Amp charge activated O O xx or xx xV Charge complete Maintain Mode started O 100 or xx xV 100A Engine...

Page 10: ...sed within the first ten minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been cha...

Page 11: ...minutes If the charger resets it sets itself for a 2A charge and 12V REGULAR battery While waiting for cranking the digital display shows the battery voltage it can t be set to percent USING YOUR ENG...

Page 12: ...signed for such batteries Activation of the spe cial desulfation mode is indicated by blinking the CHARGING LED If suc cessful normal charging will resume after the battery is desulfated The CHARGING...

Page 13: ...at period If the vehicle will only be operated for a short period short drive the battery might need to be charged again before it could start the vehicle again Reviving your battery If you only wish...

Page 14: ...if it is determined that the battery can accept the higher rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started the di...

Page 15: ...nnecting the negative large battery or a bank of battery clip Select the batteries requiring more desired charge rate and power than a 40 15 Amp battery type again if charger can deliver within necess...

Page 16: ...ANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WARRANTY THE MANUFACTURER MAKES NO WARRANTY OF MERCHANTABIL...