Warning
If additional appliances are operated in the room
where the appliance is installed or in adjoining rooms,
such as gas-fired heating systems, gas-fired in-
stantaneous water heaters, coal-fired ovens with
a chimney connection or open fireplaces, a partial
vacuum may be caused leading to the sucking back of
the exhaust gases .
►
Do not route the exhaust pipe into a fireplace that is
connected to devices such as gas or coal fired stoves
and ovens, or gas room heaters .
Condensation dis charge
At the lowest point in the exhaust air duct, you are
recommended to fit a «condensation water collector»
(proprietary) or a condensation dis charge hole of
about ø = 3 mm .
Electrical connection
Notice
Connection of the appliance to the power supply must
be carried out by a specialised electrician .
When the machine is operated for the first time
the
Data
and
Time
settings are to be checked and
if necessary, set correctly (see
Settings / Menu
Settings
in the operating instructions) .
Perform the electrical connection according to the
regulations or provisions made by the local electricity
authority and utility companies .
Approval for fixed connection, all-pole disconnectable
by a main switch .
The protective conductor connection is to be de-
signed in such a way that the protective wire only
breaks in the case of excessive tensile load after all
active (current- carrying) lines have been isolated .
In rooms in which fault-current protective switches
are required or recommended in order to increase
safety, the release current must be 30 mA .
►
Use a fault-current protective switch with the
symbol .
The motor is provided with overload protection .
The switch can be locked in the position
OFF
.
Mains cable
The appliance is delivered without mains supply cable
for connection to 3-phase alternating current with
neutral conductor (400 V 3 N ~) .
Warning
Risk of injury owing to current carrying or
rotating machine parts
►
Ensure that all the dismantled housing parts are re-fas-
tened after erecting and connecting the machine .
Risk of electric shock and risk of fire!
►
No extension cables, no multi-coupling and no plug-in,
mobile time switches may be used .
►
Do not use plug-in, mobile timer switches . The ma-
chine may not be connected via an external switching
mechanism, which regularly switches the machine on
and off (e .g . timer switch) .