Re-insert cover and drawer
►
Tighten the screws on the cover after transportation .
►
Re-insert the filter drawer .
Installation area
Maximum floor load (without socle) in operating
status:
D 200
D 325
2 125 N
2 650 N
In order to ensure the stability of the appliance during
spin drying, the installation area must be firm and
level .
Soft floor coverings, e .g . fitted carpets or coverings
with a foamed material backing are not suitable as an
installation area .
►
Keep the area surrounding the dryer free of dust and
fluff .
Keep machine dimensions in mind
Notice
The machine can be placed with its back against a
wall . The minimum distance between the machine and
the wall or possibly another machine is 50 cm .
79cm
135cm
> 50cm
90cm (D200)
120cm (D325)
►
Take note of the appliance measurements and the
space required to connect it to an exhaust air duct .
Aligning the appliance
Notice
The machine must be in a vertical position with all
four feet firmly on the floor and it must not wobble .
►
Do not remove the screw feet under any circumstances .
►
Align the appliance with the help of a spirit level on all
sides .