Store the components in a dry room.
Keep the components away from children.
5
Mounting
5.1
Optimizing radio noise suppression
To obtain good radio noise suppression and the greatest
possible operating safety, observe the following points for
expert line laying:
Mount the power packs at least 30 cm from the LED-
conducting aluminium profiles. In the process, observe
the minimum distances to the neighbouring components
(see the "Directions for use for the power pack," Fig. C).
Properly lay the output lines at a corresponding distance
to the earthed metal surfaces.
This reduces capacitive interference.
Make sure the distance between the mains cable and
connection cable of the receiver or LED strip is as large
as possible (at least 5 cm) and mains and connection
cables are not laid in parallel.
As a result, interference between the mains cable
and lamp connection cables is prevented.
Avoid intersecting the mains cable and LED modules. If
you cannot prevent an intersection, design it with the
largest possible angle as far as possible for technical
and safety reasons.
This prevent HF interference with the mains cable.