Manual
LS101 / LSW101
Schulte-Schlagbaum AG
Page 27 of 39
LS(W)101_6-703-2 30R1 4_EN.DOCX
Preparing the door for LS101 installation
According to the drawing, the following holes must be drilled in the door:
1. Hole with dimensions 19.1 mm/16 mm. Here, a hole with a
diameter of 19.1 mm is also suitable.
2. Hole with a diameter of 7 mm.
Once the 1st hole has been drilled, the 7 mm hole can be drilled using a hole pattern.
Installation
1. Insert the LS101 (
1
) in the two holes 19.1 mm/16 mm and 7 mm.
2. Fasten the LS101 (
1
) with the nuts (
2
).
3. Attach the LS101 (
1
) with the screw (
8
) and sleeve (
6
or
7
depending on the door thickness).
4. Fasten the washer (
3
) to set the direction of rotation and locking lever (
4
) by means of the
fastening screw
(5) (see note on page 6)
5. Test the functioning of the LS101 via Test Code with the door open.
6. Test the function with the door closed. Here, make sure the bolt functions
smoothly. Automatic opening can only be ensured if the bolt moves
smoothly when the door is closed.