CPCI PICMG 2.16 10 U
1.7
4 Technical data
4.1
Mechanical data
In accordance with IEC 60297, IEEE 1011.10/11
Dimensions
H x W x D = 445mm (10 U) x 483mm (19“) x 325mm
Weight (without boards)
20 kg
Heat dissipation
Provided by three axial fans.
Maximum air capacity 275 m³/h.
Average temperature increase in subrack at full load 12 K.
The fan speed depends on the temperature. The speed control
happens between 20°C and 45°C, in a range of 60% to 100%
of the maximum speed.
100 02 502
4.2 Electrical data
4.2.1 Power supply
Data of a single power supply:
Mains/line voltage
(operating ranges)
85-264Vac
Frequency
47-63Hz
Switch-on current
max.12A
Output power max.
250W
Output voltages:
max. individual current
+ 5 V
+3,3V
+ 12 V
- 12 V
40 A
40A
5,5A
1,5A
Residual ripple
2%
Dynamic load variation
50%->100%
1%
Control time after switch-on
150ms
Mains / line buffer
20ms