background image

 

Operating manual 810378-BAL-EN-170330

 

 

 Mach/30 2017

 

Page 23 of 54 

 

  LED indicators 

6.

 

Please note, these LEDs are not safety components! 
 

On the  front  side,  3 LEDs  show  continuous  information  about  the  current  supply, net-
work  and  the  HV  status.  Each  LED  has  two  colors  (red/green).  4  conditions  can  be 
displayed: off, green, red and yellow (red + green): 
 

Status LED of the power supply 

 

 

Dark: None of the 24V are on 

 

Green: Only 24 V CPU is on 

 

Yellow: 24V CPU and DRIVE are on 

 

Red: Only 24 V DRIVE is on 

 
During operation, "yellow" must be displayed. 

When accessing high voltage carrying 

parts,  "green"  or  dark  must  be  shown,  at  a  minimum  the  24V  connection  drive 
must be OFF.

 "Red" should in normal operations, never be lit. 

 

 

CAN 

 

oder 

 

 
 

CAN Bus

 

PROFINET, Ethernet/IP, Ether-

CAT

 

 

Off: No bus signal available 

  Off: No bus connected 

 

Flashes: Pre-operational 

Single flash: Stopped 

Green: Operational 

  Green: Bus connected 

 

Green/yellow: Communica-
tion error 

  Green/yellow: Trial to create 

transfer 

 

Red: Bus off 

  Yellow: Übertragung herge-

stellt 

 

High voltage status 

 

 

Green: HV off and discharged 

 

Yellow: HV switched off due to errors * 

 

Red: HV active on 

 

Dark: HV switched off and not yet discharged. 

 
*Examples of errors are: 

  I

max

 switch off 

  U

min

 switch off 

  Electrical arcing 

detected 

For other shutdowns see descriptions of the status words. 
 
After the corresponding status bit per field bus has been 
reset, the LED will either be dark or green depending on 
the residual energy. 

Summary of Contents for 810366

Page 1: ...1...

Page 2: ...rawings 17 Electrical connection 19 5 5 2 HS Erzeuger mit CAN BUS Schnittstelle 20 5 3 1 Bus connection 21 5 3 2 Supply connection 21 5 4 Grounding 22 5 5 High Voltage Connection 22 LED indicators 23...

Page 3: ...d 39 9 2 6 Describing the control word 40 9 2 7 Description of the status word 41 Specification of the Ethernet IP interface 43 10 10 1 Bus interface 43 10 2 Application interface 44 10 2 1 Receive I...

Page 4: ...ined even if the energy supply of the HV generator is disconnected for example to free access to the high voltage carrying parts There is for all Ethernet based HV supplies an option with an integrate...

Page 5: ...24 V CPU Fieldbus V measurement I measurement 24 V DRIVE R E monitor Monitoring contact 24 V CPU Fieldbus U Measurement I Measurement 24 V DRIVE HV Output Discharger Micro controller Damping resistan...

Page 6: ...class IP 65 HV Connection without Dis charger Output with 4 mm HS connector socket HV Connection with Dis charger High voltage cable installed in insulation grease Fieldbus interface CAN 2 PROFINET Et...

Page 7: ...anufacturer SCHNIER Elektrostatik GmbH Bayernstr 13 72768 Reutlingen Germany Tel 49 0 71 21 90 973 60 Fax 49 0 71 21 90 973 99 mail schnier elektrostatik de www schnier elektrostatik de Managing direc...

Page 8: ...acturer or operating company regarding this manual and the corresponding safety regulations 2 1 Accessibility to the operating manual Storing The operating manual must always be available and easily a...

Page 9: ...ter mined on the basis of their EU Type Examination Certificate in assembly with the high voltage control smart E CAUTION It is to ensure by inspection prior to commissioning and periodic testing that...

Page 10: ...HV generator is intended for operation in a specific stationary system in an industrial Due to the occurring conductive or radiated interferences difficulties can possibly arrive in ensuring the elec...

Page 11: ...e is the risk of propagating brush discharges These can occur if low thickness plastics have contact with large surface grounded conductors e g met als The dielectric strength of the coating must not...

Page 12: ...tion 4 4 1 Overview 4 1 1 HV Supply with CAN Interface High voltage plug Drive supply and monitoring contact M12 connection 5 pole B coded plug CAN bus CPU supply M12 connection 5 pole A coded plug Gr...

Page 13: ...Supply with PROFINET Ethernet IP or EtherCAT High voltage plug LED supply LED Ethernet status LED HV status Service Interface Network M12 connection 4 pin socket D cod Drive supply and monitoring cont...

Page 14: ...d must be installed replaced in the factory LED supply LED Ethernet status LED HV status Discharger connection Network M12 connection 4 pin socket D cod Drive supply and monitoring contact M12 connect...

Page 15: ...htening of the screws can cause cracks WARNING The HV generator must be installed without clearance on a grounded plate to prevent electrostatic charging of the back WARNING Do not disconnect connecti...

Page 16: ...can cause cracks WARNING The HV generator must be installed without clearance on a grounded plate to prevent electrostatic charging of the back WARNING Do not disconnect connections under voltage Gee...

Page 17: ...al 810378 BAL EN 170330 Mach 30 2017 Page 17 of 54 4 3 Dimensional drawings 4 3 1 HV supply without integrated discharger SCHNIER has 3D models and CAD files available on the product website http www...

Page 18: ...Operating manual 810378 BAL EN 170330 Mach 30 2017 Page 18 of 54 4 3 2 HV supply with integrated discharger SCHNIER has 3D models and CAD files available on the product website http www smart E310 de...

Page 19: ...d 24V CPU have to be fused with 4 A The monitoring contact is construed for max 24 V DC 1A For pass ing the performance level d it is mandatory that the conditions in Feh ler Verweisquelle konnte nich...

Page 20: ...It contains CAN bus wires and the 24 V power for the Controller CPU 2 1 5 3 4 Pin Signal Symbol 1 GND CAN 2 24 V CPU 3 GND 4 CAN H 5 CAN L Screw Shield 5 2 2 Supply Connection The supply connection i...

Page 21: ...nnection is a 4 pin M12 D coded socket 1 2 4 3 Pin Signal Symbol 1 TXD 2 RXD 3 TXD 4 RXD Screw Shield 5 3 2 Supply connection The supply connection is a 5 pin M12 A coded plug It carries the following...

Page 22: ...d bus lines 5 5 High Voltage Connection In the second step the HV cable is attached The 4 mm pin of the HV cable must be completely pushed into the HV jack in the HV generator The cable screw fitting...

Page 23: ...mum the 24V connection drive must be OFF Red should in normal operations never be lit CAN oder CAN Bus PROFINET Ethernet IP Ether CAT Off No bus signal available Off No bus connected Flashes Pre opera...

Page 24: ...enerator is also used for cooling Therefore the housing should be kept clean Never operate the device if it is defective damaged or opened Specific repair instructions If the generator must be uninsta...

Page 25: ...ia the bus system WARNING To release access to high voltage carrying parts additionally The power supply of the HV generator 24V DRIVE must be safely disconnected and secured against switching back on...

Page 26: ...this operating mode the target value I Limit must be set higher than the tar get value I max The switch off threshold I must take local and operational conditions into consideration then be determine...

Page 27: ...e set lower than the target value I max In constant current operating mode check for safe switch off of the high voltage supply The switch off threshold Umin must take local and operational conditions...

Page 28: ...switched off high voltage carrying parts of a system are still energized due to their electrical capacity Before accessing the cabin all high voltage carrying parts as described in the Safety instruct...

Page 29: ...re errors that can be confused with a closed condition It must check switch off of the supply voltage 24 V DRIVE cyclically using the set DRIVE power status bits of the HV generator To detect and excl...

Page 30: ...tage 500 V since only this value is considered safe This means concretely that the dis charge time often takes longer than 10 seconds If this discharge time is not available because for example a Bell...

Page 31: ...1 EDS Files Use our standardized EDS files to load the applications interface to your control software EDS files are simple text files that use network configuration tools to support the identificatio...

Page 32: ...the object directory and is set up as follows The objects are permanently preset 8 2 4 An example of the controls of the PDOs If there are no error messages or switch offs and 24V drive is available...

Page 33: ...to 0 depending on the system capacity To switch on the generator again the control bit HV ON must be reset and the error and switch off acknowledged This is done for example with the following RXPDO1...

Page 34: ...Operating manual 810378 BAL EN 170330 Mach 30 2017 Page 34 of 54 8 2 5 Object directory...

Page 35: ...yte 1 Byte 0 Reserve Reserve Reserve Reserve Selftest Reserve HV ON request during Relay test invalid Parameter Nodeguarding switch off Overvoltage switch off power dissipation switch off sparkover sw...

Page 36: ...e relay test bit is set the HV cannot be switched on 5 7 Reserve 1 3 0 7 Reserve 8 2 8 Description of the status word Byte Bit Status bit Description 0 0 HV display ON 1 HV creation is switched on 0 H...

Page 37: ...n ship to the input power 0 No error or error acknowledged 6 Over voltage switch off 1 An actual value above 109 kV has been detected 0 No error or error acknowledged 7 Node guarding error switch off...

Page 38: ...applications interface to your control software GSD files are simple text files that use network configuration tools to support the identification of products and their simple direction in a network S...

Page 39: ...t value for Umin switch off I Limit uA 10 800 600 0 Target value for current limit ing value 800 below 80 kV I max uA 10 800 0 Limit value for Imax switch off U actual 100 V 0 1240 Actual value kV I a...

Page 40: ...T This monitoring is initially deactivat ed and is then activated with the first heartbeat If a heartbeat never comes then the HV generator can be operated with out it As soon as the heartbeat comes o...

Page 41: ...t voltage has discharged to a safe level 0 If the high voltage is switched on or the output voltage has not been discharged to a safe level 0 If a self test error of the device has been detected 5 Res...

Page 42: ...issing DRIVE power when HV on 1 24V DRIVE is not on and HV ON has been set 0 No error or error acknowledged 6 HV ON specification during relay test 1 HV ON was set during activated relay test HV remai...

Page 43: ...hanged via the integrated webserver at http IP Adresse ipconfig CAUTION Changes should only be made here if you are knowledgeable in working with network settings If the settings no longer correspond...

Page 44: ...unit standard Data Unit Mi n Max smart E 310 Max smart E 510 Stan dard Remark U target kV 10 100 0 kV target val ue limiting value U min kV 10 100 0 Limit value for Umin switch off I Limit uA 10 300...

Page 45: ...high voltage 1 Reset error 1 All errors are confirmed 0 No action Note In order to switch on HV again after an error has been confirmed the HV ON bit must be reset set 2 Reserve 3 Reserve 4 Heartbeat...

Page 46: ...t voltage has discharged to a safe level 0 If the high voltage is switched on or the output voltage has not been discharged to a safe level 0 If a self test error of the device has been detected 5 Res...

Page 47: ...sing DRIVE power when HV on 1 24 V DRIVE is not on and HV ON has been set 0 No error or error acknowledged 6 HV ON specification during relay test 1 HV ON was set during activated relay test HV remain...

Page 48: ...ace to your control software ESI files are simple text files that use network configuration tools to support the identification of products and their simple equipping in a network SCHNIER provides an...

Page 49: ...10 Highest to lowest sensitivity Typically this parameter can be set to 5 Do not switch off electrical arc detection in normal operation Values outside of these areas min max are ignored The warning i...

Page 50: ...ontroller This monitoring is initially deactivat ed and is then activated with the first heartbeat If a heartbeat never comes then the generator can be operated without it As soon as the heartbeat com...

Page 51: ...ut voltage has discharged to a safe level 0 If the high voltage is switched on or the output voltage has not been discharged to a safe level 0 If a self test error of the device has been detected 5 Re...

Page 52: ...nd HV ON has been set 0 no error or error acknowledged 6 HV ON specification during relay test 1 HV ON was set during activated relay test HV remains off 0 no error or error acknowledged V2 01 and hig...

Page 53: ...onary electrostatic application equipment for ignitable liquid coating material Safety requirements EN 50177 2009 Stationary electrostatic application equipment for ignitable coating powders Safety re...

Page 54: ...Operating manual 810378 BAL EN 170330 Mach 30 2017 Page 54 of 54...

Reviews: