II/14
SEM
GB
2.9 Spare parts service
Visit our website www.schneider-airsys-
tems.com/td/ for the latest version of all ex-
ploded drawings and spare parts lists for our
products. If you have any special questions,
please consult the Schneider Airsystems Ser-
vice centre in your country (addresses in the
service appendix) or your local dealer.
2.10 Warranty conditions
Basis for warranty claims:
complete unit
in original condition/proof of purchase.
According to legal provisions, you re-
ceive the following warranty against
material and manufacturing defects:
private use only: 2 years,
commercial use: 1 year.
Excluded warranty claims:
Wear/consum-
able parts; improper use; overload; manipu-
lation/use for other than intended use;
insufficient/incorrect/no maintenance; accu-
mulation of dust/dirt; incorrect/impermissi-
ble work methods; failure to observe the
Instruction Manual; incorrect processing/
working materials; incorrect electrical con-
nection; improper installation.
I
Safety valve blows
out.
Vessel pressure is higher than
the set switch-off pressure.
X
Have the pressure switch reset/
replaced by a qualified person.
Safety valve is defective.
X
Replace safety valve or contact
service partner.
J
Compressor over-
heats.
Air supply not sufficient.
X
Ensure sufficient ventilation.
Cooling fins on cylinder (cylin-
der head) contaminated.
X
Clean cooling fins on cylinder
(cylinder head).
Duty cycle too long.
X
Switch off compressor.
K Oil-lubricated com-
pressor: the oil
level rises without
oil having been
added.
Condensate collects in the oil.
X
Compressor is too large, contact
service partner.
High humidity.
X
Change oil.
Problem
Cause
Remedy
Summary of Contents for SEM 255-10-50 W
Page 2: ......
Page 3: ......
Page 4: ......
Page 65: ...SEM II 47 RUS 1 2 3 Schneider Druckluft GmbH 1 X X X X X X X X...
Page 70: ...II 52 SEM RUS 2 8 X B X C X X X A X D X 2 4 4...
Page 71: ...SEM II 53 RUS E X X X X 2 6 5 X X F X G X 2 6 10 X H X 2 6 5 X E I X X J X X X...
Page 72: ...II 54 SEM RUS 2 9 www schneider airsystems com td Schneider Druckluft 2 10 2 1 K X X...
Page 73: ......