Instructions for Use
– SCHMIDT
®
LED Measured Value Display MD 10.015
Page 25
10 Technical data
Technical data
Display
Main display: 7-segments LED red; 14.2 mm; 6 digits
Sub display: 7-segments LED red; 7 mm; 2 digits
Input signals
Current:
0 /
4 … 20 mA (R
IN
= 200
Ω)
Voltage:
0 … 10 V
(R
IN
= 12.5
kΩ)
Analog output
Galvanically isolated, short-circuit protected
Permissible load resistance R
L
in signal mode:
Voltage
3
(0 … 10 V):
R
L
≥ 1 kΩ
Current
(0 / 4 … 20 mA): R
L
≤ 400 Ω
Accuracy analog output
± 0.2 % of measured value
Relay outputs
2 x relay with changeover contacts (SPDT, potential-free)
Max. 250 VAC
/ 5 A
Voltage supply for sensors
Short-circuit protected; current limited to max. 160 mA
Mat.-no. 527330: 24 VDC ± 15
%
Mat.-no. 528250
4
:
See “
” (p.
Supply voltage of display
Mat. no. 527330:
85 … 250 VAC / 50 ... 60 Hz
Mat. no. 528250: 23
… 29 VDC
Current consumption
Max. 8 VA
Operating temperature
-
20 … +60 °C
Storage/transport temperature -
40 … +70 °C
Environmental conditions
Up to 95 % RH (non-condensing)
Connection
18 x spring clamps, bare braid, Ø
≤ 1.5 mm²
4 x compression fittings
Operating position
Arbitrary
Ingress protection
IP65 (housing and screw connections tightly sealed)
Protection class
II (touch proofed)
Housing material
Polyamide, glass-fiber reinforced (PA6-GF 15/15),
color similar to RAL 7001
Weight
Approx. 370 g
Table 6
3
Current limited
4
Supply voltage of display is connected through, with a series diode & resistance of 25
.