background image

Stroboscope

DSL Series

Model   DSL-300

  

DSL-300-T

 (with trigger connection )

Operating Instructions

S C H M I D T

c o n t r o l i n s t r u m e n t s

Summary of Contents for DSL Series

Page 1: ...Stroboscope DSL Series Model DSL 300 DSL 300 T with trigger connection Operating Instructions S C H M I D T c o n t r o l i n s t r u m e n t s ...

Page 2: ...ake technical changes without prior notice We have taken the utmost care to prevent errors Liability in the event of any errors shall be excluded Printed declaration of CE conformity on request A B C D F E 1 2 3 4 5 6 7 8 9 10 11 14 12 13 ...

Page 3: ...pprox 11 h 6 000 FPM Disposable batteries approx 6 h 6 000 FPM Housing Material Aluminium ABS Heavy duty design Dimensions 191 x 82 x 60 mm Weight Approx 400g including batteries Ambient conditions Ambient temp 0 45 C Humidity Protection code IP65 Additional information for Stroboscope DSL 300 T with trigger input and output Trigger input Principle Optocoupler voltage free Low level 1 V Level 3 32...

Page 4: ...ircumstances WARNING The device may not be used in areas where there is a danger of explosion WARNING Stroboscopic light can trigger epileptic ts in susceptible people ATTENTION Repairs on the device may only be carried out by the manufacturer or the supplier ATTENTION The electronic components of the device contain substances which are harmful to the environment They must be disposed of in compli...

Page 5: ...tton is held down E Doubles the currently set value Speeds up when this button is held down F Lowers the currently set value Speeds up when this button is held down The following functions are activated by simultaneously pressing the buttons shown below B F Reset to the default settings A F Activate button lock deactivate button lock Display elds Figure 1 In uencing the set signal 1 PULS μs Flash ...

Page 6: ...e to the frequency This function enables you to set a xed angle between the internal trigger signal and the ash Example The position of observation can be adjusted extremely precisely without altering the ash frequency You can shift the observation position within a motion cycle 6 Changing the batteries Using batteries rechargeable batteries which are not completely charged reduces the operatio na...

Page 7: ...suitable for PNP and NPN signals A cable with plug corresponding to these input jacks is provided with the device Figure 2 Position of buttons Figure 1 The following functions are activated by simultaneously pressing the buttons shown below B D switch between internal and external trigger signal Display elds Figure 1 In uencing the input signal before the ash is generated 3 DELAY ms adjustment of ...

Page 8: ...h too soon With the DELAY ms function you can set the value by which the output signal should be delayed PHASE deg Phase shift adjustment between the internal trigger signal and the ash in degrees relative to the frequency This function enables you to set a xed angle between the internal trigger signal and the ash Example The external trigger signal is generated before the required observation poi...