3.8 DSL Performance Monitoring
Watson SHDSL router support DSL performance monitoring as specified in
G.SHDSL standard. The DSL performance parameters provide quantitative per-
formance information of a specific DSL link. They are intended to be used for
long-term evaluation of operating DSL links.
The DSL statistics are available with the “shdsl statistic show” command and in
the Web-base management.
3.9 Password protection
Watson SHDSL router features password protection to management functions to
prevent unauthorized access e.g. on a modem that is installed at a customer site
but is owned and managed by the service provider.
Password protection is global i.e. once the correct password is entered access to
all commands is granted.
after each
LOGOFF
after 5 minutes of inactivity
after a restart of the modem
The default user name and password are both set to 'admin'. It is recommended
to change these default values. Make sure you remember your user name and
password, since this is the only way you will be able to manage Watson SHDSL
router.
3.10 Restoring the default configuration
If the password has been lost the following procedure has to be applied:
Press the reset button located at the back of the device. After approximately
5 seconds, the LED 1 starts to blink orange, the button can be released.
The default configuration will be restored; all previous configurations will be
lost.