Schmid & Wezel
D75433 Maulbronn
Seite / Page
25/ 39
Ausführung / Version
05.2007
Figure 2: Connection plan for EFA cutters
Pressure switch
Two-hand
safety block
Compressed air P = 5-8 bar
Hose nipple
Air conditioner
Screw-in
directional control valve
Pressure switch
port
Stop
O-ring
Toothed retainer
Plastic hose
Connection of the plastic hose:
Push in the hose completely
Releasing of the plastic hose:
Press with a screwdriver onto the
outer ring of the retainer and
pull out the hose
Detail
3.1.4 Connecting and disconnecting the cut-
ter
Completely switch off the power pack at the
master switch and press switches T1 and T2
(23) simultaneously approx. 3 - 4 times. This
actuates the directional control valves and
depressurises the pressurised hydraulic return
hose (72) (see hydraulic and pneumatic circuit
diagram).
Then switch off the compressed air supply.
The two hydraulic hoses (70 + 72) and the con-
trol hose unit (76-83) can now be unscrewed.
The hydraulic couplers are self-locking so that no oil
escapes when they are disconnected.
Connecting and disconnecting the
cutter in pressure-free state!
Protect the coupling and plug parts
against soiling!
3.2 Switch operation
The cutter is equipped with a two-hand safety cir-
cuit.
3.2.1 Switching on
Hold the cutter firmly!
Figure 3:
Switches, handle
Actuate both switches simultaneously to close
the blades (Fig. 3)
The cutter may only be switched
on after reading this operating
manual and correct connection to
the power supply!