background image

EN

Operating instructions           pages 1 to 16

Original

SLC440AS

SLG440AS

Operating instructions

Safety light curtain/safety light grid

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine

Content

About this document

11  Function                                            1

12 

Target group: authorised qualified personnel

                 1

13  Explanation of the symbols used                         1

14  Appropriate use                                      2

15  General safety instructions                               2

16  Warning about misuse                                 2

17  Exclusion of liability                                    2

Product description

21  Destination and use                                   2

22  Ordering code                                        2

23  Special versions                                       2

24  Scope of delivery and accessories                         2

241 Accessories included in delivery                          2

242 Optional accessories                                  2

25  Technical data                                        3

26  Response time (reaction time)                            3

27 

Safety classification

                                   4

28  Functions                                           4

281 Fixed blanking SLC440AS                               4

282 Fixed blanking with movable edge region SLC440AS          4

283 Variable blanking SLC440AS                             5

284 Variable blanking SLG440AS                             5

29  Self-test                                             6

210  Beam coding A                                        6

211  Parameter setting                                      6

Mounting

31  General conditions                                     7

32 

Protection field and approach

                            7

33  Alignment of the sensors                               8

34  Set-up tool and set-up mode                            8

35  Safety distance                                        9

351 

Minimum distance to reflecting surfaces

                  10

36  Dimensions transmitter and receiver                       10

37  Fixing                                             12

Electrical connection

41  General information for electrical connection                13

Functions and configuration

51  Programming the slave address                         13

52 

Configuration of the safety monitor

                      13

53  Status signal "safety release"                            13

Diagnostic

61  Status information LED                                13

62  Fault diagnostic                                      14

63  AS-i diagnostics indication                              14

64  Read-out of the parameter ports                         14

65  Diagnostic signal periphery error (FID)                    14

Set-up and maintenance

71  Check before start-up                                  14

72  Maintenance                                         15

73  Regular check                                       15

74  Half-yearly inspection                                  15

75  Cleaning                                            15

Disassembly and disposal

81  Disassembly                                         15

82  Disposal                                           15

Appendix

91  Contact                                             15

10  EU Declaration of conformity

x

000 / 07

2016 / v

A

   -   103007573-EN / C / 2016-07-13 / 

AE-Nr

 6297

Summary of Contents for SLC440AS

Page 1: ...authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropriate use 2 1 5 General safety instructions 2 1 6 Warning about misuse 2 1 7 Exclusion of liability 2 2 Product descri...

Page 2: ...re strictly forbidden the manufacturer shall accept no liability for damages resulting from such invasive work arbitrary repairs conversions and or modifications to the device 2 Product description 2...

Page 3: ...AS i device insulation internal short circuit proof AS i specification Version V 3 0 Profile S 0 B F E AS i inputs Channel 1 Data bits DI 0 DI 1 dynamic code transmission Channel 2 Data bits DI 2 DI 3...

Page 4: ...ction field areas Systems with alternative beam coding A can be ordered through the type code refer to type code 2 8 1 Fixed blanking SLC440AS The SLC440AS can blank stationary objects in the protecti...

Page 5: ...ncreases the resolution In this way the physical resolution changes into an effective resolution This effective resolution must be used to calculate the safety distance Use formula 1 to calculate the...

Page 6: ...oding A must be ordered separately for each sensor transmitter and receiver 2 11 Parameter setting The parameter setting of the SLG440AS enables the individual adjustment of the desired functionality...

Page 7: ...ed as preventive warning notices to ensure a safe and appropriate handling These guidelines are an essential part of the safety instructions and therefore must always be observed and respected The SLC...

Page 8: ...permanently displayed on the receiver when the safety enabling is switched on For the optical representation of the signal quality two ranges the signal strength at the 2nd and the last beam in the p...

Page 9: ...he safety guard relays etc d Resolution of the safety light curtain The approach speed is covered with a value of 2000 mm s If value S 500 mm after the calculation of the safety distance then use this...

Page 10: ...faces must be taken into account In case of an incorrect installation interruptions of the protection field could possibly not be detected which could lead to serious injuries The hereafter specified...

Page 11: ...730 XX 730 844 863 SLC440AS ER 0810 XX 810 924 943 SLC440AS ER 0890 XX 890 1004 1023 SLC440AS ER 0970 XX 970 1084 1103 SLC440AS ER 1050 XX 1050 1164 1183 SLC440AS ER 1130 XX 1130 1244 1263 SLC440AS ER...

Page 12: ...atus display Switching condition Optional accessories Centre support MS 1110 Mounting kit consists of 2 steel angles and 4 spacers for central fixing 4 27 8 11 5 19 5 11 5 54 3 69 38 5 5 3 27 3 7 Inte...

Page 13: ...ol system through the AS i master To thiseffect the 4 input bits with the varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs in the control system 6 Diagnos...

Page 14: ...read out through the control interface of the AS i master see component description by using the Write parameter instruction with hexadecimal value F This non safe diagnostic information from the refl...

Page 15: ...middle between the transmitter and the receiver 3 No hazardous machine movement when the test rod is within the protection field 4 The hazardous machine movement comes to standstill when the voltage...

Page 16: ...13166201 Person authorized for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be downloaded from the inte...