14
Operating instructions
Safety light curtain/safety light grid
SLC 420
SLG 420
EN
3.7 Scope of delivery and accessories
3.7.1 Included in delivery
Test rod PLS
The test rod, according to the resolution is used for testing the
protection field
Mounting kit MS-1030 (SLC/SLG 420 Standard)
The mounting kit consists of 4 steel angles and 16 fixing screws
14,5
42
18,9
20
6,5
40
32
52
Mounting kit MS-1038 (SLC/SLG 420 IP69K)
The mounting kit consists of 4 pcs V4A stainless steel brackets
and 16 pcs V4A fastening screws
14,5
42
18,9
20
6,5
40
32
52
21
¤5,5
Integrated status indication (only SLG 420)
The status indication at the receiver indicates the switching condition of
the outputs OSSD1 and OSSD2
Green
= Outputs in ON state (H-signal 24V)
Red
= Outputs in OFF state (L-signal 0V)
Yellow
= Restart Interlock released / Setting mode
18
30
¤
20
3.7.2 Optional accessories
Centre fixing MS-1051
Mounting kit consists of 2 steel angles, 4 screws and 4 T-slot nuts for
central fixing
40
42
20
14,5
18,9
32
20
38
Connecting cable for transmitter
Item Number Designation
Description
Length
1207741
KA-0804
Female connector M12,
4-pole
5 m
1207742
KA-0805
Female connector M12,
4-pole
10 m
1207743
KA-0808
Female connector M12,
4-pole
20 m
Connecting cable for Receiver
Item Number Designation
Description
Length
1207728
KA-0904
Female connector M12,
8-pole
5 m
1207729
KA-0905
Female connector M12,
8-pole
10 m
1207730
KA-0908
Female connector M12,
8-pole
20 m
BUS converter NSR-0801
Converter for parameterisation and diagnostics Detailled information
can be found in the operating instructions manual of the NSR-0801
Included in delivery: integrated connecting cable, PC-software USB 20
connection (L x W x H, 122 x 60 x 35 mm), dimensions exclude cable
MSD4 Vibration damper
Kit consisting of: 8 vibration dampers 15 x 20 mm, 8 cylinder head
screws M5 with hexagon socket, 8 spring washers
The MSD4 vibration damper kit is recommend to be used for damping
vibrations and oscillations (such as presses and stamps) on the
SLC/SLG In this way, the availability of the SLC/SLG is increased