schmersal SLC 420 IP 69 K Operating Instructions Manual Download Page 9

9

EN

SLC 420 IP 69 K

Operating instructions

Safety light curtain

3.5  Dimensions

All measurements in mm

60

B

80

A

C

D

42

91

54

Legend
A

Protection field height

B

Sensor length

C

Mounting dimension

D

total length

Type

A

B

C

D

SLC 420-E/R0170-xx-69-RFB

170

267

315

351

SLC 420-E/R0250-xx-69-RFB

250

347

395

431

SLC 420-E/R0330-xx-69-RFB

330

427

475

511

SLC 420-E/R0410-xx-69-RFB

410

507

555

591

SLC 420-E/R0490-xx-69-RFB

490

587

635

671

SLC 420-E/R0570-xx-69-RFB

570

667

715

751

SLC 420-E/R0650-xx-69-RFB

650

747

795

831

SLC 420-E/R0730-xx-69-RFB

730

827

875

911

SLC 420-E/R0810-xx-69-RFB

810

907

955

991

SLC 420-E/R0890-xx-69-RFB

890

987

1035

1071

SLC 420-E/R0970-xx-69-RFB

970

1067

1115

1151

SLC 420-E/R1050-xx-69-RFB

1050

1147

1195

1231

SLC 420-E/R1130-xx-69-RFB

1130

1227

1275

1311

SLC 420-E/R1210-xx-69-RFB

1210

1307

1355

1391

SLC 420-E/R1290-xx-69-RFB

1290

1387

1435

1471

SLC 420-E/R1370-xx-69-RFB

1370

1467

1515

1551

SLC 420-E/R1450-xx-69-RFB

1450

1547

1595

1631

Accessories

3.6  Mounting kit MS-1038

14,5

42

18,9

20

6,5

40

32

52

21

¤5,5

Summary of Contents for SLC 420 IP 69 K

Page 1: ...instructions are developed to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the correct functional...

Page 2: ...s result ing from the use of unauthorised spare parts or accessories For safety reasons invasive work on the device as well as arbitrary re pairs conversions and modifications to the device are strict...

Page 3: ...olution 14 mm 0 3 10 0 m resolution 30 mm Response time 1 48 L 10 ms 49 144 L 20 ms without beam coding A 1 48 L 15 ms 49 144 L 27 ms with beam coding A Rated operating voltage 24 VDC 10 PELV supply u...

Page 4: ...as Factory setting The SLC 420 system features many functions without additional devices The following table gives an overview of the possible functions and the factory settings configuration Function...

Page 5: ...ombination of fixed and variable blanking is possible This function allows for an interruption of the protection height without the outputs being disabled in case of material movement in the protec ti...

Page 6: ...iver from foreign beams The beam coding A must be set for each sensor receiver and transmitter individually The function is activated by means of the NSR 0801 BUS converter and a PC or laptop If adjac...

Page 7: ...y guard Approach speed Resolution of the safety light curtain Safety light curtain SLC 420 The safety distance for resolutions 14 mm up to 40 mm is calculated by means of the following formula 1 S 200...

Page 8: ...13855 and EN ISO 13857 3 4 1 Minimum distance to reflecting surfaces During the installation the effects of reflecting surfaces must be taken into account In case of an incorrect installation interru...

Page 9: ...0 587 635 671 SLC 420 E R0570 xx 69 RFB 570 667 715 751 SLC 420 E R0650 xx 69 RFB 650 747 795 831 SLC 420 E R0730 xx 69 RFB 730 827 875 911 SLC 420 E R0810 xx 69 RFB 810 907 955 991 SLC 420 E R0890 xx...

Page 10: ...RD 24 VDC BN 0 VDC BU OSSD 1 GN OSSD 2 YE Earth connection Restart interlock manual reset bridge 1 By bridging DIAG IN pin 5 and DIAG OUT pin 6 the restart interlock manual reset is activated Protecti...

Page 11: ...r times 6 Power OFF 7 Remove cable bridges PIN 2 3 4 and if necessary cable bridge PIN 5 6 8 Wire OSSD 1 2 pin 3 4 9 Power ON To reverse the EDM function repeat the procedure step 2 7 If the programmi...

Page 12: ...nery parts can only be accessed by passing through the protection field of the SLC 4 The staff remains within the detection area when works are con ducted on hazardous machinery parts 5 The safety dis...

Page 13: ...D restart continuous flashing Wiring error for function selection Restart interlock manual reset automatic mode Check connection at the receiver bridge 1 or bridge 2 must be wired refer to Wiring 1 fl...

Page 14: ...accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal Tel 49 0...

Page 15: ...rson authorized for the compilation of the technical documentation Ulrich Loss M ddinghofe 30 42279 Wuppertal Notified body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n...

Page 16: ...Safety Control GmbH Am Industriepark 33 D 84453 M hldorf Inn Telefon 49 0 86 31 187 9 60 Telefax 49 0 86 31 187 9 61 E Mail info safetycontrol com...

Reviews: