5.1  Check before start-up

Prior to start-up, the following items must be checked by the responsi-

ble person

Wiring check prior to start-up

1  The voltage supply is a 24V direct current power supply, which meets 

the CE Directives, Low Voltage Directives A power downtime of 20 

ms must be bridged

2  Presence of a voltage supply with correct polarity at the SLC

3  The connecting cable of the transmitter is correctly connected to the 

transmitter and the connecting cable of the receiver correctly to the 

receiver

4  The double insulation between the light curtain output and an exter-

nal potential is guaranteed

5  The outputs OSSD1 and OSSD2 are not connected to +24 VDC

6  The connected switching elements (load) are not connected to +24 

VDC

7  If two or more SLC are used within close range compared to each 

other, an alternating arrangement must be observed Any mutual 

interference of the systems must be prevented (see chapter "Beam 

coding") 

Switch the SLC on and check the operation in the following way:

The component performs a system test during approx 2 seconds after 

the operating voltage has been switched on After that, the outputs are 

enabled if the protection field is not interrupted The LED "OSSD ON" of 

the receiver is on

In case of incorrect functionality, please follow the instructions 

listed in the chapter Fault diagnostic

5.2  Maintenance

Do not use the SLC before the next inspection is terminated 

An incorrect inspection can lead to serious and mortal inju-

ries

Conditions

For safety reasons, all inspection results must be archived The operat-

ing principle of the SLC and the machine must be known in order to 

be able to conduct an inspection If the fitter, the planning technician 

and the operator are different persons, please make sure that the user 

has the necessary information at his disposal to be able conduct the 

maintenance

5.3  Regular check

A regular visual inspection and functional test, including the following 

steps, is recommended:

1  The component does not have any visible damages

2  The optics cover is not scratched or soiled

3  Hazardous machinery parts can only be accessed by passing 

through the protection field of the SLC

4  The staff remains within the detection area, when works are con-

ducted on hazardous machinery parts

5  The safety distance of the application exceeds the mathematically 

calculated one

Operate the machine and check whether the hazardous movement 

stops under the hereafter-mentioned circumstances.

6  Hazardous machine parts do not move when the protection field is 

interrupted

7  The hazardous machine movement is immediately stopped, when 

the protection field is interrupted with the test rod immediately before 

the transmitter, immediately before the receiver and in the middle 

between the transmitter and the receiver

8  No hazardous machine movement when the test rod is within the 

protection field

9  The hazardous machine movement comes to standstill, when the 

voltage supply of the SLC is switched off

5.4  Half-yearly inspection

The following items must be checked every six months or when a ma-

chine setting is changed

1  Machine stops or does not inhibit any safety function

2  No machine modification or connection change, which affects the 

safety system, has taken place

3  The outputs of the SLC are correctly connected to the machine

4  The total response time of the machine does not exceed the re-

sponse time calculated during the first putting into operation

5  The cables, the connectors, the caps and the mounting angles are in 

perfect condition

5.5  Cleaning

If the optics cover of the sensors is extremely soiled, the OSSD outputs 

can be disabled Clean with a clean, soft cloth with exercising pressure

The use of agressive, abrasive or scratching cleaning agents, which 

could attack the surface, is prohibited

6.  Diagnostic

6.1  LED status information

Receiver

Function

LED colour

Description

Multifunction

Blanking

Signal recep-

tion

Restart
OSSD OFF
OSSD ON

Protection field

Multifunction

green

Function display, Beam coding

Blanking

blue

Protection field(s) inactive (blanking)

Signal reception

orange

Safety-monitoring module of Signal reception

Restart

yellow

Input for command device

OSSD OFF

red

Safety outputs Signal condition OFF

OSSD ON

green

Safety outputs Signal condition ON

Transmitter

Function

LED colour

Description

Transmitting

Status

Protection field

Transmitting

orange

Transmitter active

Status

green

Function display, Beam coding

Summary of Contents for SLC 420 IP 69 K

Page 1: ...instructions are developed to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the correct functional...

Page 2: ...s result ing from the use of unauthorised spare parts or accessories For safety reasons invasive work on the device as well as arbitrary re pairs conversions and modifications to the device are strict...

Page 3: ...olution 14 mm 0 3 10 0 m resolution 30 mm Response time 1 48 L 10 ms 49 144 L 20 ms without beam coding A 1 48 L 15 ms 49 144 L 27 ms with beam coding A Rated operating voltage 24 VDC 10 PELV supply u...

Page 4: ...as Factory setting The SLC 420 system features many functions without additional devices The following table gives an overview of the possible functions and the factory settings configuration Function...

Page 5: ...ombination of fixed and variable blanking is possible This function allows for an interruption of the protection height without the outputs being disabled in case of material movement in the protec ti...

Page 6: ...iver from foreign beams The beam coding A must be set for each sensor receiver and transmitter individually The function is activated by means of the NSR 0801 BUS converter and a PC or laptop If adjac...

Page 7: ...y guard Approach speed Resolution of the safety light curtain Safety light curtain SLC 420 The safety distance for resolutions 14 mm up to 40 mm is calculated by means of the following formula 1 S 200...

Page 8: ...13855 and EN ISO 13857 3 4 1 Minimum distance to reflecting surfaces During the installation the effects of reflecting surfaces must be taken into account In case of an incorrect installation interru...

Page 9: ...0 587 635 671 SLC 420 E R0570 xx 69 RFB 570 667 715 751 SLC 420 E R0650 xx 69 RFB 650 747 795 831 SLC 420 E R0730 xx 69 RFB 730 827 875 911 SLC 420 E R0810 xx 69 RFB 810 907 955 991 SLC 420 E R0890 xx...

Page 10: ...RD 24 VDC BN 0 VDC BU OSSD 1 GN OSSD 2 YE Earth connection Restart interlock manual reset bridge 1 By bridging DIAG IN pin 5 and DIAG OUT pin 6 the restart interlock manual reset is activated Protecti...

Page 11: ...r times 6 Power OFF 7 Remove cable bridges PIN 2 3 4 and if necessary cable bridge PIN 5 6 8 Wire OSSD 1 2 pin 3 4 9 Power ON To reverse the EDM function repeat the procedure step 2 7 If the programmi...

Page 12: ...nery parts can only be accessed by passing through the protection field of the SLC 4 The staff remains within the detection area when works are con ducted on hazardous machinery parts 5 The safety dis...

Page 13: ...D restart continuous flashing Wiring error for function selection Restart interlock manual reset automatic mode Check connection at the receiver bridge 1 or bridge 2 must be wired refer to Wiring 1 fl...

Page 14: ...accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal Tel 49 0...

Page 15: ...rson authorized for the compilation of the technical documentation Ulrich Loss M ddinghofe 30 42279 Wuppertal Notified body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n...

Page 16: ...Safety Control GmbH Am Industriepark 33 D 84453 M hldorf Inn Telefon 49 0 86 31 187 9 60 Telefax 49 0 86 31 187 9 61 E Mail info safetycontrol com...

Reviews: