schmersal SLC 420 IP 69 K Operating Instructions Manual Download Page 2

2

EN

SLC 420 IP 69 K

Operating instructions

Safety light curtain

The safety switchgear must be exclusively used in accordance with the 

versions listed below or for the applications authorised by the manufac-

turer Detailed information regarding the range of applications can be 

found in the chapter "Product description"

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-

tions manual, the country-specific installation standards as well as all 

prevailing safety regulations and accident prevention rules

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

wwwschmersalnet

The information contained in this operating instructions manual is pro-

vided without liability and is subject to technical modifications

If multiple safety components are wired in series, the Per-

formance Level to EN ISO 13849-1 will be reduced due to the 

restricted error detection under certain circumstances The 

entire concept of the control system, in which the safety com-

ponent is integrated, must be validated to EN ISO 13849-2

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed

Additional measures could be required to ensure that the electro-sensi-

tive device does not present a dangerous breakdown, when other forms 

of light beams are available in a special application (eg use of wireless 

control devices on cranes, radiation of welding sparks or effects of 

stroboscopic lights)

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of the 

safety switchgear, personal hazards or damages to machin-

ery or plant components cannot be excluded The relevant 

requirements of the standards EN ISO 13855 (successor of 

EN 999) and EN ISO 13857 must be observed

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual The manufacturer shall accept no liability for damages result-

ing from the use of unauthorised spare parts or accessories

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SLC 420-E/R

-

-69-RFB

No. Option

Description

xxxx

Protection field heights in mm available 

lengths: 0170, 0250, 0330, 0410, 0490, 

0570, 0650, 0730, 0810, 0890, 0970, 1050, 

1130, 1210, 1290, 1370, 1450

14

Resolution 14 mm  

with a range of 03 m … 7 m

30

Resolution 30 mm with a  

range of 03 m … 10 m

Only if the information described in this operating instruc-

tions manual are realised correctly, the safety function and 

therefore the compliance with the Machinery Directive is 

maintained

2.2  Special versions

For special versions, which are not listed in the order code below 21, 

these specifications apply accordingly, provided that they correspond to 

the standard version

2.3  Scope of delivery and accessories

Accessories included in delivery

Connecting cable for emitter and receiver

Cable length 5,0 m, cable connector M12 x 1; 4-pole fixed to transmit-

ter, M12 x 1; 8-pole fixed to receiver integrated

Mounting kit MS-1038

The kit includes 4 mounting angles, material V4A and 16 fixing screws, 

material V4A for fixation to the end caps

Test rod PLS

The test rod is used for testing the protection field

Optional accessory

Connecting cable for transmitter
Item Number

Designation

Description

Length

1207741

KA-0804

Female connector M12, 4-pole 5 m

1207742

KA-0805

Female connector M12, 4-pole 10 m

1207743

KA-0808

Female connector M12, 4-pole 20 m

Connecting cable for Receiver
Item Number

Designation

Description

Length

1207728

KA-0904

Female connector M12, 8-pole 5 m

1207729

KA-0905

Female connector M12, 8-pole 10 m

1207730

KA-0908

Female connector M12, 8-pole 20 m

BUS converter NSR-0801

Converter for parameterisation and diagnostics Detailled information 

can be found in the operating instructions manual of the NSR-0801

Included in delivery: integrated connecting cable, PC-software USB 20 

connection (L x W x H, 122 x 60 x 35 mm), indications of measure-

ments without cable

Summary of Contents for SLC 420 IP 69 K

Page 1: ...instructions are developed to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the correct functional...

Page 2: ...s result ing from the use of unauthorised spare parts or accessories For safety reasons invasive work on the device as well as arbitrary re pairs conversions and modifications to the device are strict...

Page 3: ...olution 14 mm 0 3 10 0 m resolution 30 mm Response time 1 48 L 10 ms 49 144 L 20 ms without beam coding A 1 48 L 15 ms 49 144 L 27 ms with beam coding A Rated operating voltage 24 VDC 10 PELV supply u...

Page 4: ...as Factory setting The SLC 420 system features many functions without additional devices The following table gives an overview of the possible functions and the factory settings configuration Function...

Page 5: ...ombination of fixed and variable blanking is possible This function allows for an interruption of the protection height without the outputs being disabled in case of material movement in the protec ti...

Page 6: ...iver from foreign beams The beam coding A must be set for each sensor receiver and transmitter individually The function is activated by means of the NSR 0801 BUS converter and a PC or laptop If adjac...

Page 7: ...y guard Approach speed Resolution of the safety light curtain Safety light curtain SLC 420 The safety distance for resolutions 14 mm up to 40 mm is calculated by means of the following formula 1 S 200...

Page 8: ...13855 and EN ISO 13857 3 4 1 Minimum distance to reflecting surfaces During the installation the effects of reflecting surfaces must be taken into account In case of an incorrect installation interru...

Page 9: ...0 587 635 671 SLC 420 E R0570 xx 69 RFB 570 667 715 751 SLC 420 E R0650 xx 69 RFB 650 747 795 831 SLC 420 E R0730 xx 69 RFB 730 827 875 911 SLC 420 E R0810 xx 69 RFB 810 907 955 991 SLC 420 E R0890 xx...

Page 10: ...RD 24 VDC BN 0 VDC BU OSSD 1 GN OSSD 2 YE Earth connection Restart interlock manual reset bridge 1 By bridging DIAG IN pin 5 and DIAG OUT pin 6 the restart interlock manual reset is activated Protecti...

Page 11: ...r times 6 Power OFF 7 Remove cable bridges PIN 2 3 4 and if necessary cable bridge PIN 5 6 8 Wire OSSD 1 2 pin 3 4 9 Power ON To reverse the EDM function repeat the procedure step 2 7 If the programmi...

Page 12: ...nery parts can only be accessed by passing through the protection field of the SLC 4 The staff remains within the detection area when works are con ducted on hazardous machinery parts 5 The safety dis...

Page 13: ...D restart continuous flashing Wiring error for function selection Restart interlock manual reset automatic mode Check connection at the receiver bridge 1 or bridge 2 must be wired refer to Wiring 1 fl...

Page 14: ...accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal Tel 49 0...

Page 15: ...rson authorized for the compilation of the technical documentation Ulrich Loss M ddinghofe 30 42279 Wuppertal Notified body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n...

Page 16: ...Safety Control GmbH Am Industriepark 33 D 84453 M hldorf Inn Telefon 49 0 86 31 187 9 60 Telefax 49 0 86 31 187 9 61 E Mail info safetycontrol com...