5.3 Mounting instructions for ADP... type control elements (orde-
ring sufix E1 or E2) and ADRR40 type emergency stop command
devices
General:
• The ADP... type pushbuttons are by default suitable for mounting up to
a wall thickness of max. 4 mm (increased wall thickness possible with
modiied thread ring). The maximum tightening torque for the device
head to tighten the thread ring with an A-14 tool is 1 Nm.
• The supplied EDT-12 double-sided adhesive gasket must be adhered
under the device head prior to the disassembly of the device (to adjust
and secure the pushbutton). The protective ilms of the gasket must
be previously removed.
a)
Fig. 1: a) Front plate
Fig. 2
Fig. 3
a)
Fig. 4: a) Securing plate
5.4 Mounting instructions for EDRR EFR and KDRR EFR type
emergency stop command devices
• Fit the EDR EFR emergency stop actuator in non-actuated condition
by means of the ELM mounting lange, align and tighten (max. 0.6
Nm).
• Snap the EFR spring element in the middle position of the EFM
mounting lange (position 3). The EFR spring element is supplied in
tensioned condition.
• The EDR EFR actuator is latched, i.e. mechanically ixed, to the EFR
spring element by actuation. By rotating to the right and consecutive
pulling, the spring element is retensioned and the emergency stop
command device is brought back to its basic position.
• Snap the EF contact element(s) into position(s) 1 (and/or 2) of the
EFM mounting lange.
• EFR spring element: to avoid itting errors, we recommend to it the
enclosed locking plate (A) by means of both locking rings (B) 4 mbo
09 after the contacts have been snapped on (see photo). No special
tools are required. This locking plate ensure a proper itting and ixati-
on of the contact elements.
B
A
Fig. 5
• The emergency stop device is now ready for operation.
5.5 Mounting instructions for EDR type emergency stop command
devices
• Fit the EDRZ emergency stop actuator in non-actuated condition by
means of the EFM mounting lange, align and tighten (max. 0.6 Nm).
Do not actuate the emergency stop actuator!
• Snap the EF contact element(s) into position(s) 1 (and/or 2 and 3) of
the EFM mounting lange.
• The emergency stop device is now ready for operation.
5.6 Mounting instructions for BWT sensor button
In constructions for the assembly and putting into operation of
BWT-1/BWT-2, the requirements of EN 574 must be impera-
tively observed!
Deinition of "two-hand control panel"
A two-hand control panel requires a simultaneous actuation with both
hands to start and maintain the operation of a machine, as long as
there are risks. A two-hand control panel must be located outside the
hazardous area, to prevent the operator from entering this area before
the machine has come to a complete standstill.