schmersal PROTECT SELECT Operating Instructions Manual Download Page 15

15

PROTECT SELECT

PROTECT SELECT OEM

Operating instructions

Multifunctional safety controller

EN

Timers used

Name Function

Timer

Time [s]

TOF 0 Shut down delay for Q0/Q0N

T00

0.00

TOF 2 Shut down delay for Q2

T02

0.00

TOF 3 Shut down delay for Q3

T03

0.00

TOF 4 Shut down delay for QR1

T04

0.00

TOF 5 Shut down delay for QR2

T05

0.00

Monitoring time for MSP 1 (E-Stop)

T07

10.00

Monitoring time for MSP 2

T08

10.00

Monitoring time for MSP 3

T09

10.00

Monitoring time for MSP 4

T10

10.00

Monitoring time for MSP 5

T11

10.00

Monitoring time for MSP 6

T12

10.00

Stable time for MSP 1 (E-Stop)

T13

0.10

Stable time for MSP 2

T14

0.10

Stable time for MSP 3

T15

0.10

Stable time for MSP 4

T16

0.10

Stable time for MSP 5

T17

0.10

Stable time for MSP 6

T18

0.10

Stable time for MSP 7 (analogue E-Stop) T19

1.00

Application program 03

Prog_03:  One safety area, visible from control area,  

5 x individual sensors,  

1 x Emergency-Stop command device (variable sensors)

(CRC 055E)

Connection example

Terminal assignment of the digital inputs

I00

START / RESET  
or latch interlock

for I02 up to I11

I01

Unlock solenoid interlock

I02 + I03

1. sensor:

MSP 2 (Default value=0 0 0)

I04 + I05

2. sensor:

MSP 3 (Default value=0 0 0)

I06 + I07

3. sensor:

MSP 4 (Default value=0 0 0)

I08 + I09

4. sensor:

MSP 5 (Default value=0 0 0)

I10 + I11

5. sensor:

MSP 6 (Default value=0 0 0)

I12

---

I13

Feedback circuit

I14

---

I15

START / RESET  
or latch interlock

for I16 + I17

I16 + I17

Emergency stop  
command device,

MSP 1 (Default value=0 A 1)

Terminal assignment of the outputs

Q0, Q0N

Stop 0 or Stop 1 

with fail-safe timer T00

Option with selection "Latch": working or quiescent current

Q2

Stop 0 or Stop 1 

with fail-safe timer T01

Q3

Stop 0 or Stop 1 

with fail-safe timer T02

QR1

Stop 0 or Stop 1 

with fail-safe timer T03

QR2

Stop 0 or Stop 1 

with fail-safe timer T04

Terminal assignment of the signalling outputs  

(optionally digital input)

Y0 (I00)

---

Y1 (I04)

---

Y2 (I12)

without delay OFF / delayed ON with timer T06

Y3 (I14)

Signalling output: error message / status indication:
Error messages

= ON

Warnings

= Flashing ON with 1Hz

Program description

The application program is based on a monitored visible safety area.

There is only a general requirement that lock and unlock all controlled 

interlocks.

The user has the option of connecting 5 individual sensors to the 

inputs I02 to I11. The condition START / RESET via the input I00 is 

 permanently assigned to the inputs I02 to I11.

In addition, the inputs can be changed as individual sensors I16 and 

I17 together with the default setting "Emergency Stop command 

device". The condition START / RESET via the input I15 is permanently 

 assigned to the inputs I16 to I17.

The connected sensors switch off the outputs Q0/Q0N, Q2 and Q3, 

QR1 and QR2.

Summary of Contents for PROTECT SELECT

Page 1: ...neral information for electrical connection 4 4 2 Power supply 4 4 3 Start level 4 4 4 Sensor level 4 4 5 Actuator level 5 5 Operating principle and settings 5 1 Connection operating elements 6 5 2 De...

Page 2: ...se If used incorrectly or not for the intended purpose or in the case of tampering danger to persons or damage to machine and system parts from using the safety module cannot be ruled out 1 7 Exclusio...

Page 3: ...t change Sinusoidal max 2 8 Hz max 50 mA s Input resistance 10 k Safe analogue inputs Category PL SIL CL Single channel If a cable break dominates Cat 3 PL d SIL CL 2 Dual channel Cat 4 PL e SIL CL 3...

Page 4: ...d pins Electrical power cables must be routed separately from communication lines 3 2 Disassembly Unlock the bottom of the enclosure by means of a slotted screwdriver push up and hang out slightly til...

Page 5: ...onductor outputs Q2 Q3 with 24 VDC 2 x safe relay outputs QR1 QR2 with common supply QR0 up to 250 VAC or 24 VDC 4 x operational optional message outputs Y0 Y 3 with 24 VDC Relay outputs 250 V 24V GND...

Page 6: ...y outputs Operational outputs signalling output Clock outputs for the supply of safe digital inputs for short circuit recognition 5 3 Start level Alternatively auto start or manual start falling edge...

Page 7: ...processor MSP which is parameter assigned by a three digit hexadecimal number The 1 position describes the sensor the 2 position the additional function and the 3 position the contact properties The e...

Page 8: ...ing locked guard interlocks Power to lock For solenoid locked guard interlocks The interlock type always applies to all connected guard interlocks Analog inputs Dual Sensor 2 channel analysis of AI0 a...

Page 9: ...the list After entry a plain text display of the selected settings appears ENTER moves back to the code list display If you navigate up with the last MSP code the next menu appears MSP 01 1 A 5 MSP 0...

Page 10: ...leshooting Description of possible error cause and rectification measures Restart Trigger of a new start once the error has been eliminated Configuration Enter PIN Entry of the PIN codes so as be able...

Page 11: ...essary Sensors and emergency stop command devices can be reset in any order Sensor level Safe analogue inputs Implemented in the following application programs for both analogue secure inputs are the...

Page 12: ...ital inputs I00 I01 Operating mode selector switch automatic I00 HIGH I01 LOW manual I00 LOW I01 HIGH I02 I03 Enabling switches MSP 6 Default value 0 0 0 I04 I05 1 sensor MSP 2 Default value 0 0 0 I06...

Page 13: ...ayed Signalling output Y3 error message status indication Manual mode Flashing with 2Hz Warning Flashing with 1Hz Error messages Lights up Safe semi conductor outputs Q0 Q0N Stop 0 or Stop 1 All semic...

Page 14: ...lay outputs QR1 QR2 Stop 0 or Stop 1 All relay outputs are linked to a safe timer Timer Off Delay Stop 0 Timer 0 seconds Default value Stop 1 Timer should be actively adjusted to 0 seconds Application...

Page 15: ...4 sensor MSP 5 Default value 0 0 0 I10 I11 5 sensor MSP 6 Default value 0 0 0 I12 I13 Feedback circuit I14 I15 START RESET or latch interlock for I16 I17 I16 I17 Emergency stop command device MSP 1 De...

Page 16: ...00 Monitoring time for MSP 5 T11 10 00 Monitoring time for MSP 6 T12 10 00 Stable time for MSP 1 E Stop T13 0 10 Stable time for MSP 2 T14 0 10 Stable time for MSP 3 T15 0 10 Stable time for MSP 4 T1...

Page 17: ...conductor outputs are linked to a safe timer Timer Off Delay Stop 0 Timer 0 seconds Default value Stop 1 Timer should be actively adjusted to 0 seconds Safe relay outputs QR1 QR2 Stop 0 or Stop 1 All...

Page 18: ...The muting monitoring time continues The muting lamp Y0 remains on The muting outputs remain set e The workpiece releases the light barrier AOPD The muting monitoring time continues The muting lamp Y0...

Page 19: ...art the safety monitoring the high signal is absent at the corresponding input which means the feedback loop of the integrated actuator is not closed Timeout Disturbed safety switch The time lag betwe...

Page 20: ...56 12103 Berlin ID n 0035 Person authorized for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal P...

Reviews: