background image

2

Operating instructions

Safety sensor

EX-BNS40S

EN

1.6  Warning about misuse

In case of improper use or manipulation of the safety 

switchgear, personal hazards or damages to machinery 

or plant components cannot be excluded. The relevant 

requirements of the standard ISO 14119 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

EX-BNS40S-12Z

-

-3GD

No. Option

Description

without LED

G

with LED

Through-holes

C

Rear-side threaded hole

Actuator

BPS40S-1, BPS40S-2,  

BPS40S-1-C, BPS40S-2-C

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond  

to the standard version.

2.3  Purpose

The safety sensor is designed for application in safety circuits and is 

used for monitoring the position of movable safety guards to ISO 14119 

and IEC 60947-5-3. The safety sensor can be used for monitoring 

the position of movable guards and flaps in explosion-endangered 

areas of Zone 2 and 22 category 3GD. Installation and maintenance 

requirements to the standard series EN 60079 must be met.

The safety switches are used for applications, in which the hazardous 

situation is terminated without delay when the safety guard is opened. 

To actuate the safety sensors, only the above-mentioned actuators can 

be used.

The safety switchgears are classified according to ISO 14119 

as type 4 interlocking devices.

Only the entire system consisting of the safety sensor, the actuator and 

the safety-monitoring module meets the requirements of the standard 

IEC 60947-5-3.

The safety sensor is especially suitable for food-processing machinery 

and plants. Due to the stainless steel enclosure, the safety sensor is 

resistent to corrosion and cleaning agents. The safety sensor is suitable 

for concealed mounting behind non-ferromagnetic covers.

Conditions for safe operation

The energy restriction for LED versions (24 V/10 mA) must be ensured 

by the user.

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level. 

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards. 

2.4  Technical data

Equipment category: 

L

 II 3GD

Ex protection: 

Ex nAnC IIC T6 Gc; 

Ex tc IIIC T80 °C Dc 

Standards:

 

IEC 60947-5-3, BG-GS-ET-14,  

EN 60079-0, EN 60079-15, EN 60079-31, ISO 80079-36

Design:

 rectangular

Enclosure: 

stainless steel V4A  

(material desgination according to DIN 1.3960)

Max. impact energy:

 

7 J

Protection class:

 

IP65 / IP67 to IEC 60529 

termination:

 

LIYY cable, 1 m (food safe)

Cable section:

 

6 × 0.25 mm²

Operating principle:

 magnetic

Actuating magnet:

 

BPS40S-1, BPS40S-2,  

BPS40S-1-C, BPS40S-2-C, coded

Coding level according to ISO 14119:

 low

assured switching distance s

ao

:

 

8 mm

assured switch-off distance s

ar

:

 

18 mm

Switching condition indication:

 

LED only with ordering suffix G

Switching voltage:

 

max. 24 VAC/DC

Switching current:

 

 

- without LED: 

 

max. 250 mA 

- with LED:

 

max. 10 mA

Switching capacity:

 

 

- without LED:

 

max. 3 W 

- with LED:

 

max. 240 mW

Required short-circuit current:

 

100 A

Ambient temperature: 

−20 °C … +60 °C

Storage and transport temperature:

 

−25 °C … +80 °C

Switching frequency:

 

 max. 5 Hz

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

10 … 55 Hz, amplitude 1 mm

2.5  Safety classification

Standards: 

ISO 13849-1

B

10D

 (NC/NO contact):

 25,000,000

notice:

 

at 20% contact load

Service life: 

20 years

MTTF

B

d x

x

h

s/h

3600

D

10D

op

op

op

n

0,1 x n

op

t

cycle

(Determined values can vary depending on the application-specific 

parameters h

op

, d

op

 and t

cycle

 as well as the load.)

If multiple safety components are wired in series, the Performance 

Level to ISO 13849-1 will be reduced due to the restricted error 

detection under certain circumstances.

Summary of Contents for EX-BNS40S

Page 1: ...lity of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions man...

Page 2: ... consisting of the safety sensor the actuator and the safety monitoring module meets the requirements of the standard IEC 60947 5 3 The safety sensor is especially suitable for food processing machinery and plants Due to the stainless steel enclosure the safety sensor is resistent to corrosion and cleaning agents The safety sensor is suitable for concealed mounting behind non ferromagnetic covers ...

Page 3: ... magnetic spacer of at least 5 mm thick must be used The use of non magnetic fixing screws is recommended also Do not subject the safety sensor and actuator to extreme vibrations and shocks Keep away from metal chips The mounting distance between two sensors should always be at least 50 mm Also suitable for concealed mounting behind non ferromagnetic covers Safety sensor and actuator must be perma...

Page 4: ...ices that do not require an earth connection 4 2 Contact variants The contact position shows the actuated sensor function when the safety guard is closed For safety sensors with LED the LED is illuminated when the safety guard is closed The contact configurations of the versions with or without LED are identical S14PK GNS21 GYS13 WHS31 S22YE S32BN 4 3 Connection The safety sensor is suitable for u...

Page 5: ...ance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Fitting of the sensor and the actuator 2 Fitting and integrity of the power cable 3 The system is free of dirt and soiling in particular metal chips 5 2 Maintenance In the case of correct installation and adequate use the safety sensor features maint...

Page 6: ...ed to in Appendix IV 2014 34 EU TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal September 11 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddingho...