background image

5

EX-BNS40S

Operating instructions

Safety sensor

EN

Technically, multiple safety sensors can be wired to one AES/SRB 

safety-monitoring module.  To connect multiple safety sensors (check 

if authorised!), their NO contacts are wired in parallel and their NC 

contacts in series. The Protect-IE-11 or -02 or PROTECT-PE-11 (-AN) 

or -02 input expander module can be used to connect up to 4 safety 

sensors with NC/NC or NC/NO contacts.

Safety sensors equipped with LED's shall not be wired in series, 

except for the Protect-IE input expander module. As a result of this, 

the luminosity of the LED's would considerably decrease and the 

voltage could drop below the minimum input voltage of the downstream 

safety-monitoring module. Please observe that the diagnostic coverage 

could reduce if multiple safety sensors are connected to one safety-

monitoring module.

In case of series-wiring at SRB max. 1 sensor with LED 

indication for U

N

.

5.  Set-up and maintenance

5.1  Functional testing

The safety function of the safety components must be tested.  

The following conditions must be previously checked and met:

1. Fitting of the sensor and the actuator.

2. Fitting and integrity of the power cable.

3.  The system is free of dirt and soiling  

(in particular metal chips).

5.2  Maintenance

In the case of correct installation and adequate use, the safety sensor 

features maintenance-free functionality.

A regular visual inspection and functional test, including the following 

steps, is recommended:

• Check of the safety function

• Check the fitting of the sensor and the actuator.

• Remove possible metal chips.

• Check the cable for damage.

Adequate measures must be taken to ensure protection against 

tampering either to prevent tampering of the safety guard, for 

instance by means of replacement actuators.

Damaged or defective components must be replaced.

6.  Disassembly and disposal

6.1  Disassembly

The safety switchgear must be disassembled in a de-energised 

condition only.

6.2  Disposal

The safety switchgear must be disposed of in an appropriate manner  

in accordance with the national prescriptions and legislations.

Summary of Contents for EX-BNS40S

Page 1: ...lity of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions man...

Page 2: ... consisting of the safety sensor the actuator and the safety monitoring module meets the requirements of the standard IEC 60947 5 3 The safety sensor is especially suitable for food processing machinery and plants Due to the stainless steel enclosure the safety sensor is resistent to corrosion and cleaning agents The safety sensor is suitable for concealed mounting behind non ferromagnetic covers ...

Page 3: ... magnetic spacer of at least 5 mm thick must be used The use of non magnetic fixing screws is recommended also Do not subject the safety sensor and actuator to extreme vibrations and shocks Keep away from metal chips The mounting distance between two sensors should always be at least 50 mm Also suitable for concealed mounting behind non ferromagnetic covers Safety sensor and actuator must be perma...

Page 4: ...ices that do not require an earth connection 4 2 Contact variants The contact position shows the actuated sensor function when the safety guard is closed For safety sensors with LED the LED is illuminated when the safety guard is closed The contact configurations of the versions with or without LED are identical S14PK GNS21 GYS13 WHS31 S22YE S32BN 4 3 Connection The safety sensor is suitable for u...

Page 5: ...ance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Fitting of the sensor and the actuator 2 Fitting and integrity of the power cable 3 The system is free of dirt and soiling in particular metal chips 5 2 Maintenance In the case of correct installation and adequate use the safety sensor features maint...

Page 6: ...ed to in Appendix IV 2014 34 EU TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal September 11 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddingho...

Reviews: