Voltage drop U
d
, maximum
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A
Electrical data - Serial diagnostic SD
Operation current
150 mA
Wiring capacitance
50 nF
Status indication
Note (LED switching conditions display)
Operating condition: LED green
Error / functional defect: LED red
Supply voltage UB: LED green
Pin assignment
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT serial diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN serial diagnostic input
Note about the safety classification
2
The safety consideration of the guard locking function only applies for standard devices with monitored solenoid interlock
AZM300Z-…-1P2P-… (see Ordering code). A safety assessment of the guard locking function for devices with serial diagnostics
"SD2P" is not allowed due to the non-safe locking/unlocking signal from the SD Gateway.
2
If for a certain application the power to unlock version of a solenoid interlock cannot be used, for this exception an interlock
with power to lock can be used if additional safety measure need to be realised that have an equivalent safety level.