AZM150-C-EN

Operating instructions

Solenoid interlock

AZM150

Production site: 

SCHMERSAL

Industrial Switchgear (Shanghai) Co., Ltd.

Cao Ying Road 3336

201712 Shanghai / Qingpu, P.R.CHINA

Phone:  +86-21-63 75 82 87

Fax: 

+86-21-69 21 43 98

E-Mail:   [email protected]

Internet:   www.schmersal.com.cn

施迈赛工业开关制造(上海)有限公司

地址:上海市青浦区漕盈路3336号
邮编:201712

电话:021-63 75 82 87
传真:021-69 21 43 98

网址 www.schmersal.com.cn

The currently valid declaration of conformity can be  

downloaded from the internet at products.schmersal.com.

Name of the component:

AZM150

Type:

See ordering code

Description of the component:

Interlocking device with electromagnetic interlock for safety 

functions

Relevant Directives:

Machinery Directive

EMC-Directive

RoHS-Directive

2006/42/EC

2014/30/EU

2011/65/EU

Applied standards:

EN 60947-5-1:2017

EN ISO 14119:2013

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

Place and date of issue:

Shanghai, April 1, 2021

Authorised signature

Michele Seassaro

Managing Director

EU Declaration of conformity

Original

SCHMERSAL

Industrial Switchgear (Shanghai) Co., Ltd.

Cao Ying Road 3336

201712 Shanghai / Qingpu

P.R.CHINA

http://www.schmersal.com.cn

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

7.  EU Declaration of conformity

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30, 42279 Wuppertal

Germany

Phone:  +49 202 6474-0

Telefax:  +49 202 6474-100

E-Mail: [email protected]

Internet: www.schmersal.com

Summary of Contents for AZM150

Page 1: ...exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all pre...

Page 2: ...pose The solenoid interlock has been designed to prevent in conjunction with the control part of a machine movable safety guards from being opened before hazardous conditions have been eliminated The AZM150 solenoid interlocks with individual coding offer a higher protection against tampering and remain off when the guard system is unlocked or open Interlocks with power to lock principle may only ...

Page 3: ...on category AC 15 DC 13 Rated operating current voltage Ie Ue 4 A 230 VAC 4 A 24 VDC Rated impulse withstand voltage Uimp 4 kV Rated insulation voltage Ui 300 V Thermal test current Ithe 5 A Max fuse rating 6 A gG Required rated short circuit current 1 000 A Rated control voltage Us 24 VDC 110 VAC 230 VAC Electrical data Magnet control Magnet switch on time 100 Power consumption max 8 5 W Accepted...

Page 4: ...gs must be sealed with slot sealing plugs Detailed information on actuators with standard coding not included in delivery AZM150 B1 AZM150 B5 and AZM150 B6 and their mounting can be found in the actuator operating instructions The insertion funnel on the head of the interlock allows insertion of a flexible actuator with an axial offset of 1 and a height offset of 1 The actuator must be inserted in...

Page 5: ...ting or welding the insertion depth of the actuator is not modified There are different actuator types available The actuators AZM150 B1 and AZM150 B5 are preferably used for sliding and removable safety guards For hinged guards the AZM150 B6L or AZM150 B6R actuator When the switch is fitted on a hinged safety guard please ensure that the point of rotation is located within the range of the upper ...

Page 6: ...ectrical connection 4 1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de energised condition If the risk analysis indicates the use of a monitored interlock they are to be connected in the safety circuit with the contacts indicated with the symbol Appropriate cable glands with a suitable degree of protection are to be u...

Page 7: ...3 3 4 4 11 5 Set up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Fitting of the solenoid interlock and the actuator 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 4 Check that both the cover side and rear manual releases are in the st...

Page 8: ...Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 1 2017 EN ISO 14119 2013 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Shanghai April 1 2021 Authorised signature Michele Seassaro Managing Director EU Declaration of conformity Original...