6
Operating instructions
Solenoid interlock
AZM150
EN
Actuator AZM150-B5
20
10
ø5
,5
23
42
90°
46
2
Installation position with actuator inserted
(all measurements ± 0.3 mm)
21.8
41.8
26
61.8
38.5
18.5
Actuator AZM150-B6L
Actuator AZM150-B6R
28
34
43
44
11
ø
5.5
28
34
43
ø
5.5
44
11
Installation position with actuator inserted
(all measurements ± 0.3 mm)
23
18,5
58.8
3.4 Accessories
Designation / description
Ordering code
Triangular key
TK-M5
101100887
Lockout tag
SZ150-1
153027887
Cable gland
M20 x 1,5
on request
Tamperproof screws M5 x 15, 2
(incl. washers)
on request
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
If the risk analysis indicates the use of a monitored interlock
they are to be connected in the safety circuit with the
contacts indicated with the symbol .
Appropriate cable glands with a suitable degree of protection are to be
used. The desired insertion opening should be opened with a suitable
tool.
After wiring, the wiring compartment must be cleaned (i.e. remove
excess cables etc.).
Max. cable section:
0.25 … 1.5 mm²
(incl. conductor ferrules without plastic collar)
Removing the cable
sheathing
Y
A1
A2
1.
1.
2.
2.
3.
3.
4.
4.
11-
y = 71 mm
y = 67 mm
y = 57 mm
y = 47 mm
y = 37 mm
Settle length x of the conductor:
6 mm
X
X