1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol indicates useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

products.schmersal.com.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.5 

Safety classification of the interlocking function

. . . . . . . . . . . . . . . .3

2.6 

Safety classification of the interlock function

. . . . . . . . . . . . . . . . . .3

3  Assembly

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.3  Mounting of individually coded actuators. . . . . . . . . . . . . . . . . . . . .5

3.4  Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .6

4.2  Contact Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

4.3  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7  EU Declaration of conformity

Version 2

x.000 / 05.2021 / v

.A. - 103041686-EN / 

A / 2021-05-31 / 

AE-Nr

. -

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for AZM150

Page 1: ...exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all pre...

Page 2: ...pose The solenoid interlock has been designed to prevent in conjunction with the control part of a machine movable safety guards from being opened before hazardous conditions have been eliminated The AZM150 solenoid interlocks with individual coding offer a higher protection against tampering and remain off when the guard system is unlocked or open Interlocks with power to lock principle may only ...

Page 3: ...on category AC 15 DC 13 Rated operating current voltage Ie Ue 4 A 230 VAC 4 A 24 VDC Rated impulse withstand voltage Uimp 4 kV Rated insulation voltage Ui 300 V Thermal test current Ithe 5 A Max fuse rating 6 A gG Required rated short circuit current 1 000 A Rated control voltage Us 24 VDC 110 VAC 230 VAC Electrical data Magnet control Magnet switch on time 100 Power consumption max 8 5 W Accepted...

Page 4: ...gs must be sealed with slot sealing plugs Detailed information on actuators with standard coding not included in delivery AZM150 B1 AZM150 B5 and AZM150 B6 and their mounting can be found in the actuator operating instructions The insertion funnel on the head of the interlock allows insertion of a flexible actuator with an axial offset of 1 and a height offset of 1 The actuator must be inserted in...

Page 5: ...ting or welding the insertion depth of the actuator is not modified There are different actuator types available The actuators AZM150 B1 and AZM150 B5 are preferably used for sliding and removable safety guards For hinged guards the AZM150 B6L or AZM150 B6R actuator When the switch is fitted on a hinged safety guard please ensure that the point of rotation is located within the range of the upper ...

Page 6: ...ectrical connection 4 1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de energised condition If the risk analysis indicates the use of a monitored interlock they are to be connected in the safety circuit with the contacts indicated with the symbol Appropriate cable glands with a suitable degree of protection are to be u...

Page 7: ...3 3 4 4 11 5 Set up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Fitting of the solenoid interlock and the actuator 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 4 Check that both the cover side and rear manual releases are in the st...

Page 8: ...Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 1 2017 EN ISO 14119 2013 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Shanghai April 1 2021 Authorised signature Michele Seassaro Managing Director EU Declaration of conformity Original...