schmersal AZM 200 D Operating Instructions Manual Download Page 1

AZM 200 D

Operating instructions

Safety switch with interlocking function

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional  

information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed  

to execute safety-related functions as part of an entire plant or machine. 

It is the responsibility of the manufacturer of a machine or plant to 

ensure the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

products.schmersal.com.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3 

Retrofit kit for Emergency release/Emergency exit

  . . . . . . . . . . . . .4

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .4

5  Operating principle and diagnostic functions

5.1  Magnet control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.2  Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .5

5.3  Diagnostic-LEDs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.4  Operating principle of the electronic diagnostic output  . . . . . . . . . .5

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

8  Appendix

8.1  Wiring example  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

8.2 

Wiring configuration and connector accessories

. . . . . . . . . . . . . . .7

9  EU Declaration of conformity

x.000 / 04.2020 / v

.A. - 101216309-EN / C / 2020-03-27 / 

AE-Nr

. 12184

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for AZM 200 D

Page 1: ...ted below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention r...

Page 2: ...he safety guard is open or unlocked The safety switchgears are classified according to ISO 14119 as type 4 interlocking devices Safety switches with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk since the safety guard can be opened immediately on failure of the power supply or upon activation of the main switch The user must evaluate and...

Page 3: ... 60947 5 3 PL d Control Category 3 PFH 1 x 10 7 h SIL suitable for SIL 2 applications Mission time 20 years 3 Mounting 3 1 General mounting instructions Please observe the relevant requirements of the standards ISO 12100 ISO 14119 and ISO 14120 For fitting the safety switch and the actuator two mounting holes for M6 screws with washers washers included in delivery are provided The safety switch mu...

Page 4: ...to ISO 13849 1 The outputs cannot be wired in series Inductive loads e g contactors relays etc are to be provided with suitable interference suppression circuitry Requirements for the connected safety monitoring module Dual channel safety input suitable for 2 or 4 p type semi conductor outputs Safety outputs Y1 Y2 The safety monitoring module must tolerate internal functional with cyclic switch of...

Page 5: ...t immediately affect the safe functionality of the safety switch will lead to a delayed shut down refer to table 2 After fault rectification fault at output Y1 or Y2 temperature fault the fault is acknowledged by opening and relocking the relevant guard door The safety outputs enable and allow a restart An interlocking chain must be permanently locked to enable the reactivation Automatic electroni...

Page 6: ...N3 IN1 IN2 SRB S12 A1 S22 A2 24VDC 0V S12 A1 S22 A2 24VDC 0V Table 1 the diagnostic function of the AZM 200 D safety switch System condition Solenoid control IN LED LED LED Safety outputs Diagnostic output Power to unlock Power to lock green red yellow Y1 Y2 Y3 Y4 OUT Safety guard open 24 V 0 V 0 V 24 V On Off Off 0 V 0 V 0 V 24 V 0 V Door closed actuator not inserted 24 V 0 V On Off Flashes 3 Hz ...

Page 7: ... output 4 6 VT 6 PK PK Y2 Safety output 2 7 RD 7 VT BU IN Solenoid control 8 PK 8 OR shielded RD LED LED 9 9 Key button Input output 10 10 Key button Input output 11 11 NC 12 12 Connector plug ST1 M23 8 1 pole Connector plug ST2 M12 8 pole Connector plug ST M23 12 pole 1 2 9 3 4 5 6 7 8 5 8 4 3 2 1 7 6 10 12 11 9 8 7 6 5 4 3 2 1 Connecting cables with female connector IP67 M23 8 1 pole 8 x 0 75 mm...

Page 8: ...romagnetic inter lock for safety functions Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 3 2013 ISO 14119 2013 EN ISO 13849 1 2015 EN 61508 parts 1 7 2010 EN 62061 2005 AC 2010 A1 2013 A2 2015 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 EC prototyp...

Reviews: