8.2  Wiring configuration and connector accessories

Function  

safety switchgear

Pin configuration of the 

connector

Colour code or  

conductor numbering  

of the below-mentioned  

Schmersal connectors

Possible colour code of other  

commercially available connectors

to  

IEC 60947-5-2

DIN 47100

A1

U

e

1

BN

1

BN

WH

OUT

Diagnostic output

2

WH

2

WH

BN

A2

GND

3

BU

3

BU

GN

Y1 

Safety output 1

4

BK

4

BK

YE

Y3

Safety output 3

5

GY

5

GY

GY

Y4

Safety output 4

6

VT

6

PK

PK

Y2 

Safety output 2

7

RD

7

VT

BU

IN

Solenoid control

8

PK

8

OR / shielded

RD

LED

LED+

9

9

Key button

Input/output

10

10

Key button

Input/output

11

11

NC

-

12

12

Connector plug ST1 M23, (8+1)-pole

Connector plug ST2 M12, 8-pole

Connector plug ST M23, 12-pole

1

2

9

3

4

5

6

7

8

5

8

4

3

2

1

7

6

10

12

11

9

8

7

6

5

4

3

2

1

Connecting cables with female connector 

IP67, M23, (8+1)-pole - 8 x 0.75 mm²

Connecting cables with female connector 

IP67, M12, 8-pole - 8 x 0.25 mm²

Connecting cables with female connector 

IP67, M23, 12-pole - 12 x 0.75 mm²

Cable length

Part number

Cable length

Part number

Cable length

Part number

5.0 m

10.0 m

101209959

101209958

2.5 m

5.0 m

10.0 m

103011415

103007358

103007359

5.0 m

101208520

Summary of Contents for AZM 200 D

Page 1: ...ted below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention r...

Page 2: ...he safety guard is open or unlocked The safety switchgears are classified according to ISO 14119 as type 4 interlocking devices Safety switches with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk since the safety guard can be opened immediately on failure of the power supply or upon activation of the main switch The user must evaluate and...

Page 3: ... 60947 5 3 PL d Control Category 3 PFH 1 x 10 7 h SIL suitable for SIL 2 applications Mission time 20 years 3 Mounting 3 1 General mounting instructions Please observe the relevant requirements of the standards ISO 12100 ISO 14119 and ISO 14120 For fitting the safety switch and the actuator two mounting holes for M6 screws with washers washers included in delivery are provided The safety switch mu...

Page 4: ...to ISO 13849 1 The outputs cannot be wired in series Inductive loads e g contactors relays etc are to be provided with suitable interference suppression circuitry Requirements for the connected safety monitoring module Dual channel safety input suitable for 2 or 4 p type semi conductor outputs Safety outputs Y1 Y2 The safety monitoring module must tolerate internal functional with cyclic switch of...

Page 5: ...t immediately affect the safe functionality of the safety switch will lead to a delayed shut down refer to table 2 After fault rectification fault at output Y1 or Y2 temperature fault the fault is acknowledged by opening and relocking the relevant guard door The safety outputs enable and allow a restart An interlocking chain must be permanently locked to enable the reactivation Automatic electroni...

Page 6: ...N3 IN1 IN2 SRB S12 A1 S22 A2 24VDC 0V S12 A1 S22 A2 24VDC 0V Table 1 the diagnostic function of the AZM 200 D safety switch System condition Solenoid control IN LED LED LED Safety outputs Diagnostic output Power to unlock Power to lock green red yellow Y1 Y2 Y3 Y4 OUT Safety guard open 24 V 0 V 0 V 24 V On Off Off 0 V 0 V 0 V 24 V 0 V Door closed actuator not inserted 24 V 0 V On Off Flashes 3 Hz ...

Page 7: ... output 4 6 VT 6 PK PK Y2 Safety output 2 7 RD 7 VT BU IN Solenoid control 8 PK 8 OR shielded RD LED LED 9 9 Key button Input output 10 10 Key button Input output 11 11 NC 12 12 Connector plug ST1 M23 8 1 pole Connector plug ST2 M12 8 pole Connector plug ST M23 12 pole 1 2 9 3 4 5 6 7 8 5 8 4 3 2 1 7 6 10 12 11 9 8 7 6 5 4 3 2 1 Connecting cables with female connector IP67 M23 8 1 pole 8 x 0 75 mm...

Page 8: ...romagnetic inter lock for safety functions Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 3 2013 ISO 14119 2013 EN ISO 13849 1 2015 EN 61508 parts 1 7 2010 EN 62061 2005 AC 2010 A1 2013 A2 2015 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 EC prototyp...

Reviews: