Description of Functions
EN-US · 30.30.01.01721 · 01 · 09/19
35 / 66
7.9 Rotating the Display [0x004F]
To allow different installation positions, the orientation of the display can be rotated by 180° by changing
the parameter [
dPY
] in the configuration menu or via IO-Link.
The factory setting is [
5td
]. This corresponds to the standard configuration.
To rotate the display by 180°, select the parameter setting [
rot
].
With the display rotated, the
and
buttons switch functions. The Down button becomes
the Up button.
The decimal points of the display are shown on the top edge of the screen.
When the display is rotated, the decimal point on the far right is no longer displayed and is
therefore missing from the display of the counters and serial numbers.
7.10 ECO Mode [0x004C]
The ejector offers the option of switching off the display or dimming it to save energy. If ECO mode is ac-
tivated, the display is switched off to reduce system power consumption after 1 minute if no buttons are
pressed.
ECO mode can be enabled and disabled with the parameter [
Eco
] in the configuration menu or via IO-
Link.
Three different settings are available:
•
[
off
]: Energy-saving mode is disabled.
•
[
Lo
]: The brightness of the display is reduced by 50 percent after 1 minute.
•
[
on
]: The display switches off after one minute of inactivity.
The display is reactivated by pressing any button or by an error message.
If you activate ECO mode using IO-Link, the display will immediately enter energy-saving
mode.
7.11 Locking and Unlocking the Menus
The menus can be protected from unwanted access by means of a PIN code [
P1n
] or in the IO-Link using
Device Access Locks. The current settings are still displayed.
The PIN is set to 000 on delivery. The menus are not protected.
A PIN is recommended because carrying out parameterization while the device is in operation
can change the status of signals.
7.11.1 PIN Code [0x004D]
To enable the lock, a valid PIN code between 001 and 999 must be entered in parameter [
P1n
] in the
configuration menu or via IO-Link.
When the lock is active, [
Loc
] flashes in the display or the PIN code is requested.
The following describes how to set a PIN Code using the operating and display element.
1. Press the
button for at least three seconds.
ð
The display will flash [
-
C
-
] during this process.
ð
The configuration menu opens.
2. Use the
or
button to select the parameter [
P1n
].
3. Confirm using the
button.