Operating and Menu Concepts
22 / 66
EN-US · 30.30.01.01721 · 01 · 09/19
Starting the system menu:
4
Press
and
simultaneously for about three seconds.
ð
The display flashes [
-5-
]
ð
The system menu opens with the first parameter [
cc1
].
5.1.2 Displaying the Operating Mode and Supply Voltages (Slide Show)
When you press the
button in the basic operating state, the following parameters are automatically
displayed one after the other on the display (slide show):
•
The current operating mode (
510
or
10L
)
•
The supply voltages U
S
and U
A
The display cycle returns to the vacuum display after a complete cycle or can be canceled at any time by
pressing any button.
5.1.3 Displaying the System Pressure
4
Press the
button to show the current system pressure.
ð
The system pressure is displayed.
4
Press the
button to exit the system pressure display.
On the variant without a built-in pressure sensor, the values are specified via the IO-Link.
5.1.4 Displaying the vacuum/pressure unit
4
Press the
button to display the set vacuum/pressure unit.
After about two seconds, the screen returns to the vacuum display.
5.2 Main Menu
All settings for standard applications can be accessed and configured using the main menu.
5.2.1 Functions in the Main Menu
The following table shows an overview of the display codes and parameters in the main menu:
Display
code
Parameter
Explanation
x-1
Limit value H1
Deactivation value of control function
(only if [
ctr
] = [
on
] is active)
h-1
Hysteresis value h-1
Hysteresis value for the control function
x-2
Limit value H2
Switching value for the "Parts control" signal
h-2
Hysteresis value h-2
Hysteresis value for the "Parts control" signal
XP1
Limit value H1
Switching value for the "Pressure control" signal
hP1
Hysteresis hP1
Hysteresis value for the "Pressure control" signal
tbL
Ventilation time
Blow-off time setting for time-controlled blow-off (only if [
blo
] =
[
1-t
] or [
E-t
] is active)
CAL
Zero-point adjust-
ment (calibration)
Calibrate vacuum sensor, zero point = ambient pressure