Operating and Menu Concepts
EN-US · 30.30.01.01721 · 01 · 09/19
23 / 66
5.2.2 Changing the Parameters of the Main menu
1. Press the
button briefly.
2. Use the
or
button to select the desired parameter.
3. Confirm using the
button.
4. Use the
or
button to change the value.
5. If the menu is locked: Enter a valid PIN code.
6. Press the
button to save the modified value.
ð
The displayed value flashes to confirm.
ð
The display automatically jumps to the next setting value.
Tips and Tricks for Parameter Setting
•
By pressing the
or
button for approx. 3 seconds, the value to be changed is
scrolled through quickly
•
If you exit the modified value by briefly pressing
, the value will remain unchanged.
5.3 Configuration Menu
The configuration menu is available for applications with special requirements.
5.3.1 Functions in the Configuration Menu
The following table shows an overview of the display codes and parameters in the configuration menu:
Display
code
Parameter
Possible settings
Explanation
ctr
Energy-saving
function
oFF
on
on5
Control function off
Control active
Control with leak monitoring active
dc5
Deactivate
auto. control
shutoff
NO
YE5
Suppresses the automatic valve protection function
when set to
YE5
.
Cannot be activated when
Ctr
=
off
.
t-1
Max. permissi-
ble evacuation
time
configurable be-
tween 0.01 and
9.99 seconds in
steps of 0.01
off
Permissible evacuation time; evaluation in IO-Link
only
No monitoring
-L-
Max. permissi-
ble leakage
Values config-
urable between
0
and
999
Menu item only displayed when
ctr
=
On5
Unit: Millibar per second
This value is used for onS and CM warnings. The
adjustable leakage value can be used to judge the
quality of the suction process. Evaluation in IO-Link
only.
bLo
Blow-off func-
tion
-E-
1-t
E-t
Externally controlled
Internally controlled (triggered internally, time can
be set)
Externally controlled (triggered externally, time can
be set)
dLY
Switching sig-
nal delay
Values:
10
,
50
,
200
and
oFF
Delays switching signals
X1
,
XP1
and
X2
Unit: milliseconds