DESCRIPTION OF FUNCTIONS
www.schmalz.com
EN | 35
6.2.2.3
Extended system state
The category of the pending event code and the current event code (IO-Link event) itself are shown
via the ISDU parameter 138 "Extended Device Status".
ISDU
Dec
Parameter
Value
Hex
Description
138
Extended Device Status
–
Event Category
0x10
System is working correctly
0x21
Warning
– Low
0x22
Warning
– High
0x41
Critical state
– Low
0x42
Critical state
– High
0x81
Defect
– Low
0x82
Defect
– High
For more information, see the chapter “IO-Link events.” There is also a detailed display in the IODD.
6.2.2.4
NFC status
The NFC data transmission status is transmitted as follows.
ISDU
Dec
Parameter
Value
Hex
Description
139
NFC status
0x00
Write process complete with correct data
0x23
Write error: No write access
0x30
Write error: Parameter outside the limit value
0x41
Write error: Contradictory parameters
0xA1
Write error: No authorization
0xA2
No NFC connection
0xA3
Write error: Incorrect data structure
0xA5
Write process not complete yet
0xA6
Internal NFC error