![Schmalz FMHD Series Operating Instructions Manual Download Page 43](http://html.mh-extra.com/html/schmalz/fmhd-series/fmhd-series_operating-instructions-manual_1212859043.webp)
30.30.01.01648/03
www.schmalz.com
EN | 43
7.
To inspect the contamination level in the
base profile
, completely remove the end cover. You can
blow out the gripper with compressed air. When removing the functional cover, ensure that the
hose connection to the separating cylinder is disconnected.
8.
To inspect that condition of the sealing on the sealing plate of the compact cylinder, unscrew the
four outer screws of the mounting plate and remove the separating cylinder assembly unit (B) (note
the hose). The sealing must be intact and free of tears. To do this, proceed as follows:
Remove the functional cover, disconnect the compressed air hose for controlling the separating
cylinder.
Unscrew the four fastening screws of the cylinder mounting plate.
Remove the mounting plate from the system together with the cylinder.
Inspect the hoses, quick exhaust valve and T section and blow them out with compressed air if
necessary.
See also chapter 2.2.1.
Check the sealing. Remove any defective sealing, adhesive residue or other contamination. The
adhesive surfaces must be kept clean and dry before the new seal can be attached.
Attach the replacement seal.
Reinstall the cylinder, connect it to the pneumatic hose and quick-change valve, and reattach
the mounting plate. Ensure that the pneumatic hose is not bent or positioned in a way that
would impair the function of the separating cylinder.
Afterwards, perform a leak test.
Compressed air connection
to the separating cylinder
Compressed air con-
nection to the housing
cover
Connecting the separating cylinder
T-section
ventilation
Cylinder ventilation
Ventilation