Vacuum area gripper
5.2
The system is mounted on the load suspension provided by the customer (e.g. a gantry crane or ro-
bot) using the T-slots designated for this purpose. The customer also provides a control device.
The suspension should be designed to allow the system to adapt flexibly to the workpieces when it is
placed on them (e.g. spring-mounted or floating suspension).
The system must be attached securely, taking the weight of the system and its maximum load-bearing
capacity into account.
We recommend fastening the area gripper via two connection points for every four sliding blocks (see
Accessories).
Pneumatic Connection
5.3
1. Electrical connection
2. Compressed air pneumatic coupling
3. Gauge
4. Ventilation
The compressed air is connected using the quick-connect coupling, which is located on the sealing
plate and is included in delivery. Requirements for the compressed air provided by the customer:
Dry, filtered air according to ISO 8573-1:2010 [7:4:4]
Constant operating pressure: 6 bar.
If you select a supply hose that is too small, the compressed air supplied to the pneumatic elements
will not be enough for optimal operation.
Maximum overpressure
The maximum overpressure in the gripper (vacuum reservoir or valve chamber)
must be limited to a maximum of 0.2 bar.
Ventilation
The opening for ventilating the valve may not be closed. In order to maintain the
functionality of the gripper, the ventilation must always be operated with direct blow-
off.