Error
Possible cause
Solution
Pneumatic cylinder is
not working
Cylinder is defective
Repair cylinder or replace if necessary
Operating pressure is too low
Set the compressed air supply to 6 bar;
check the supply lines (is the hose bent
or disconnected?)
Inspect the solenoid valve
Dirt; defective, control
Solenoid valve is not
working
Electrical control is not working
Check the connections and replace
valve if necessary
Solenoid valve is defective
Repair or replace the solenoid valve
Recommendation
We recommend always performing tests with original sample workpieces. We would
be happy to help you with testing.