Setting-up of the Diver-Hub webportal
Installation of Diver-Gate driver
The Diver-Gate driver is a computer program that controls the Diver-Gate(S) (or Diver-Gate(M)) when connected to
a computer through a USB cable. The driver can be downloaded as an executable from the swstechnology website
(www.swstechnology.com). Appendix VI contains the driver installation steps.
Installation of Diver-Office software
Diver-Office 2012.1 or higher is needed to configure the Diver and Diver-DXT devices. The software can be
downloaded for free from the swstechnology website (www.swstechnology.com). Users who already have installed
an older version of Diver-Office can update directly from within the Diver-Office software.
Programming of Diver dataloggers
The Diver dataloggers can be programmed with a Diver USB reading unit and Diver-Office software. For more
information about programming Diver dataloggers see the Diver manual on the swstechnology website.
Connect Diver to a DXT cable and a Diver-DXT
The Diver is screwed on the bottom connector of the DXT cable and the Diver-DXT is screwed on the top connector
of the DXT communication cable. Through the safety cords the Diver-DXT can be secured to the communication
cable. See illustration for more details.
The radio is deactivated during shipment to the client. The radio will automatically activate (turn on) when the
Diver-DXT is connected to a Diver via a DXT cable. The clock of the Diver-DXT will automatically synchronize once
a day (at midnight) with the clock of the attached Diver datalogger. After activation the radio module is awake
during the day from 7:00 AM until 23:00 PM, waking up every 14 seconds. During the night from 23:00 PM to 7:00 AM
the radio is asleep and only wakes up once every 5 minutes. The radio can’t be deactivated (turned off) by the user.
Setup network ID in Diver-DXT
A network identification or network ID is a password in the Diver-DXT that allows the Diver-Gate(S) (or Diver-
Gate(M)) to connect to a Diver-DXT. The Diver-DXTs are shipped with a default network ID (1234). It is strongly
recommended to change the default network ID before using the Diver-DXT. Furthermore it is advisable to setup
different network ID‘s in case a Diver-DXT is within radio range of two or more Diver-Gate(S) devices. This will
make sure that a Diver-DXT can only be scanned and readout by a single Diver-Gate(S).
The network ID in the Diver-DXT can be setup with Diver-Office. For more information see the Diver-Office help
section 5.2 (Configuring network settings) and 5.3.1 (Changing Diver-DXT settings).
Start barologger Diver-DXT
The barologger inside the Diver-DXT can be started with the following software:
•
Diver-Office 2012.1. For more information see the Help section within the Diver-Office software.
•
Diver-Mobile. For more information see the Diver-Mobile manual on the swstechnology website.
It is important to note that the right network ID should be selected within the software to match with the network ID
of Diver-DXT.
Summary of Contents for Diver-NETZ
Page 27: ...February 2014 www swstechnology com copyright of SLB Appendix I ...
Page 34: ...February 2014 www swstechnology com copyright of SLB Appendix II ...
Page 36: ...February 2014 www swstechnology com copyright of SLB Appendix III ...
Page 39: ...February 2014 www swstechnology com copyright of SLB Appendix IV ...
Page 41: ...February 2014 www swstechnology com copyright of SLB Appendix V ...
Page 43: ...February 2014 www swstechnology com copyright of SLB Appendix VI ...
Page 46: ...February 2014 www swstechnology com copyright of SLB Appendix VII ...
Page 48: ...February 2014 www swstechnology com copyright of SLB Appendix VIII ...