Schleuniger CCM 1200
39
Replacing upper blade
Switch the master switch off. Remove the mains plug from the power supply. The
following work must only be carried out by specially trained personnel (Schleuniger
representatives, the user’s trained specialist personnel).
•
Remove the cover
together with the ejector
shaft (Figure 12, Page
37).
•
Remove the upper screw
on the connector rod. It is
secured with a
lock nut
(Figure 15).
Caution: The upper
knife will now fall
down!!
•
Clean the inside using a
paintbrush and vacuum
cleaner attachment
•
Remove the upper blade
(two M5 socket head
screws).
•
After you have lightly
oiled the new or the
resharpened blade you
can fit it back.
Figure 15. Replacing upper blade
•
Move the upper blade up and down. The blade should not jam or have any play. Carry out a
manual cutting test using a strip of paper. The strip should be cut evenly along the entire cutting
length. If the quality of the cut is poor then you must realign the blades. The procedure for
realigning is described on Page 41.
•
Tighten the screws on the connector rod
(!! Don’t forget the lock nut)
.
•
Fit the cover and connect the mains plug to the power supply.
Sharpening the blades
Your Customer Service Department will be
pleased to sharpen your blades for you.
However, if you wish to sharpen the blades
yourself then you must do this on the front
edges.
Figure 16. Sharpening the blades
Screws upper
blade
upper blade
bottom blade
Nuts bottom
blade
Screw
connector rod
connectro
rod
Stirn-
seiten
oberes Messer
unteres Messer